5
5.5 Air filter check
Important
•
Before proceeding with operation, read
•
When the cartridge G is dirty, do not clean it but
replace cartridges B and G.
NOTE: Components not necessarily supplied by KOHLER .
1. Release the two clasps F of the cover A .
2. Remove the cartridges B and G .
3. Clean the inside components A and D with a damp
cloth.
4. Do not use compressed air , repeatedly tap the front
side E on a flat surface.
5. Reinstall:
- cartridges G and B.
- the cover A checking the right tightness of clasps F .
5.6 Check of the radiator heat - exchanger surface
Danger
•
For safety precautions see
NOTE: Component not necessarily supplied by KOHLER .
Important
•
Before proceeding with operation, read
•
Wear safety goggles when using compressed air.
•
The radiator heat-exchange surface must be cleaned
on both.
1. Check the radiator heat-exchange surface D .
2. Clean the surface with a brush soaked in special
detergent if it is clogged.
EN
38
INFORMATION ABOUT MAINTENANCE
Chap. 3
.
Par. 3.2.2
.
Fig 5.5
Fig 5.6
Par. 3.2.2
.