NOTE: Before proceeding with any operation on the engine, stop it and
allow it to cool.
Warning
Presence of steam pressurized coolant danger of burns.
1. Loosen the cap A and fill the radiator with coolant composed of:
50% ANTIFREEZE and 50% decalcified water.
2. Top liquid up until the pipes inside the radiator are covered by
about 5 mm. Do not overfill the radiator, but leave room for the
coolant to expand.
3. For engines equipped with expansion tank, pour in fluid until
reaching the max level mark.
4. Loosen the screw C, release any air and tighten the screw C
(Tightening torque of 50 Nm - Fig. 4.5).
5. Re-tighten the cap A.
6. After a few hours of operator, stop the engine and allow the
liquid to cool returns to a ambient temperature and check the
coolant level again.
Fig. 4.5