INFORMATION ABOUT MAINTENANCE
5

5.4 Air filter check

NOTA: Components not necessarily supplied by KOHLER.
1. Pull insert F to unlock cover A.
2. Rotate counter clockwise and remove cover A.
3. clean the inside components A and D with a damp cloth.
4. Do not use compressed air, repeatedly tap the front side E on a flat
surface.
Important
When the cartridge G is dirty, do not clean it but replace
cartridges B and G.
5. Fit cartridges G and B.
6. Fit cover A by performing the operations indicated in points 2 and 1
in the reverse order.

5.5 Check of the radiator heat - exchanger surface

Danger
• For safety precautions see
NOTE: Component not necessarily supplied by KOHLER .
Important
• Before proceeding with operation, read
• Wear safety goggles when using compressed air.
The radiator heat-exchange surface must be cleaned on both.
1. Check the radiator heat-exchange surface D .
2. Clean the surface with a brush soaked in special detergent if it is
clogged.