Technical Data; 150I, Es 180I - ESAB Rogue ES 150i Service Manual

Hide thumbs Also See for Rogue ES 150i:
Table of Contents

Advertisement

TECHNICAL DATA

TECHNICAL DATA
ES 150i, ES 180i
Technical data
Outlet voltage
Primary current
I
MMA
max
I
 Live TIG
max
No-load power demand when in
energy saving mode
Setting range
MMA
Live TIG
Permissible load at MMA
20% duty cycle
25% duty cycle
60% duty cycle
100% duty cycle
Permissible load at Live TIG
25% duty cycle
60% duty cycle
100% duty cycle
Apparent power I
at maximum
2
current
Active
power I
2
at maximum current
Power factor at maximum current
Live TIG
MMA
Efficiency at maximum current
MMA
Live TIG
Open-circuit voltage U
VRD 35 V deactivated
VRD 35 V activated
Operating temperature
0463 714 001
Rogue ES 180i
230 V±15%
1~ 50/60 Hz
36 A
24 A
30 W
20-180 A
10-180 A
170 A / 26.8 V
97 A / 23.9 V
75 A / 23 V
180 A / 17.2 V
116 A / 14.6 V
90 A / 13.6 V
8.7 kVA
5.5 kW
0.63
0.63
89%
89%
max
0
63 V DC
<30 V
-10 to +40 °C
(+14 to 104 °F)
- 34 -
Rogue ES 150i
230 V±15%
1~ 50/60 Hz
30 A
18.5 A
30 W
20-150 A
10-150 A
150 A / 26 V
97 A / 23.9 V
75 A / 23 V
150 A / 16 V
97 A / 13.9 V
75 A / 13 V
6.9 kVA
4.35 kW
0.63
0.63
89%
89%
63 V DC
<30 V
-10 to +40 °C
(+14 to 104 °F)
© ESAB AB 2023

Advertisement

Table of Contents
loading

Table of Contents