VBW
The FIP base and option cards connection diagrams
indicate for every digital input and output the relevant
INTECONT VEG parameter numbers used for
distribution on physical signals.
The tables below compares the connector
assignments of FIP and VEG for all physical signals.
Digital Outputs
FIP
Physical Signal
X1
1,2
DA1
X1
3,4
DA2
X1
5,6
DA3
X6
1,2
DA4
X6
3,4
DA5
X6
5,6
DA6
X6
7,8
DA7
X6
9,10
DA8
Digital Inputs
FIP
Physical Signal
X3
1,2
DE1
X9
1,2
DE2
X9
3,4
DE3
—-
DE4
—-
DE5
X3
5,6
Sensor = (DE6)
X5
1,2
V1 (Tacho 1) = DE7
X3
3,4
V2 (Tacho2)
Analog Inputs/Outputs
FIP
Physical Signal
X9
9,10
A01
—-
A02
—-
AI
Replacement Instructions
BV-H2214 GB
112
Load Cell
FIP
X5
X5
X5
X5
X5
X5
Attention:
VEG
Signals IN1 and IN2 are swapped between FIP and
VEG. (VEG is compatible to DISOCONT).
X1
1,2
X1
3,4
X1
5,6
X8
1,2
Power Supply
X8
3,4
X8
5,6
X8
7,8
FIP
X8
9,10
X2
X2
X2
X2
VEG
Printer
X3
1,2
X3
3,4
X6
6,7
FIP
X9
1,2
X9
3,4
X8
X3
5,6
X8
X7
1,2
X8
—-
Pulse Output
FIP
VEG
X9
X6
4,5
X9
X9
5,6
X9
X9
X6
1,2,3
With VEG, fieldbus is connected via separate fieldbus
cards (FIP: Connector X7). See Fieldbus Manual
BVH2220.
Technische
Redaktion PDE-RD
INTECONT PLUS
Physical Signal
3
OUT1
4
REF1
5
IN2
6
IN1
7
REF2
8
OUT2
Physical Signal
1
0V ext
2
24V ext
3
ext. 0V supply
4
ext. 24V supply
Physical Signal
1
Screen
2
TX
3
RX
Physical Signal
5
24V
6
Open collector
7
Open emitter
8
0V
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.
VEG
X7
3
X7
4
X7
6
X7
5
X7
7
X7
8
VEG
X2
1
X2
2
X2
3
X2
4
VEG
X10
1
X10
2
X10
3
VEG
X6
8
X6
9
X6
10
X6
11