Conversion From Ng To Lp - Regency Fireplace Products Panorama P33E Owners & Installation Manual

Zero clearance direct vent gas fireplace, natural gas/propane
Table of Contents

Advertisement

installation
|
44

Conversion from NG to LP

For P33E-11 Using SIT 885 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT
Each Kit contains one LPG
Conversion Kit Part #438-977
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-575
Burner Orifice #55
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1
910-037
LPG Injector
(Pilot Orifice)
1
911-011
Hi/Lo Conversion LP
1
920-029
Instruction Sheet
Installation of the LPG
Conversion Kit:
1.
Shut off the gas supply.
2.
Remove the mesh barrier (see manual)
and glass door.
a) Release the two hooks from the
bottom of the glass door.
b) Swing the door out 45 degrees from
the bottom - then lift up and out.
3. Remove logs and brick panels if
installed.
4.
Remove the 2 screws holding the Burner
Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.
Remove the 2 screws, push Burner
Assembly to the left and lift out.
44 |
Regency
P33E-11 Zero Clearance Direct Vent Gas Fireplace
®
920-029
Conversion from NG to LPG
for P33CE using SIT 886 NOVA Gas Valve
DO NOT DO THIS CONVERSION!!
5. Undo clip and remove pilot cap to
expose pilot orifice.
Pilot Cap
6.
Unscrew the pilot orifice with the Allen
key and replace with the LPG pilot orifice
in the kit and replace pilot cap.
7.
8.
9. Remove regulator and discard. Install the
Clip
10. Attach the label "This unit has been
11. Replace yellow "NG" label with red "LPG"
12. Reverse step 3 - 1
13. Check for gas leaks.
14. Check inlet and outlet pressures.
15. Check operation of flame control.
These instructions must remain
1
P33E
Remove burner orifice with a 1/2"
wrench and discard. Use another wrench
to hold on to the elbow behind
the orifice.
Burner Orifice
Reinstall new burner orifice LPG
stamped #55 and tighten.
Hi/Lo pressure regulator onto the valve
with 2 screws as shown below.
converted to LPG" near or on top of the
serial # decal.
label.
Installer Notice:
with the appliance.
01.14.19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panorama p33e-ng11Panorama p33e-lp11

Table of Contents