Conversion Kit From Ng To Lp - Regency Fireplace Products Contura RC500E Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Conversion Kit From NG to LP

CONVERSION KIT FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
This conversion kit shall be installed by a quali-
fi ed service agency in accordance with the
manufacturer's instructions and all applicable
codes and requirements of the authority having
jurisdiction. If these instructions is not followed
exactly, a fi re, explosion or production of carbon
monoxide may result causing property damage,
personal injury or loss of life. The qualifi ed ser-
vice agency is responsible for the proper instal-
lation of this kit. The installation is not proper
and complete until the operation of the convert-
ed appliance is checked as specifi ed in the man-
ufacturer's instructions supplied with the kit.
LP Conversion Kit Contains: (Part #366-977)
Qty
Part #
1
904-529
1
904-163
1
918-590
1
908-528
1
910-037
1
911-011
1
920-049
Installation of LP Conversion Kit:
1.
Shut off the gas and electrical supply.
2.
Lift off the front safety screen (if installed) and open the front door
(see details in manual).
3.
Remove the logs, and any media (if already installed).
4.
Remove the front grill - see manual.
5.
Remove the 3 screws holding the Burner Assembly to the fi rebox
base. Lift burner straight up and lift out to remove.
920-049
IF IN DOUBT DO NOT DO THIS CONVERSION !!
WARNING
Description
5/32" Allen Key
Burner Orifi ce #54
Label "Converted to LPG"
Red "LPG" label
LP Injector (Pilot Orifi ce)
Stepper Motor
Instruction Sheet
6.
Loosen both screws on pilot hood cover. Pivot cover to the left
to reveal pilot hood.
7.
Lift off pilot cap to expose pilot orifi ce.
8.
Unscrew the pilot orifi ce with the supplied Allen key and replace
with the LP pilot orifi ce in the kit --replace pilot cap.
9.
Remove burner orifi ce with a 1/2" wrench and discard. Use another
wrench to hold on to the elbow behind the orifi ce.
Burner Orifi ce
10. Reinstall new burner orifi ce LP stamped #54 and tighten.
11. Open the lower access door by pulling open to the left.
12. Lift off component access cover to remove (see manual for
details).
installation
RC500E-11
01.29.19
RC500E-11 |
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Contura rc500e-ng11Contura rc500e-lp11