Conversion From Ng To Lp/Ulpg - Regency Fireplace Products Greenfire GF900L Owners & Installation Manual

Table of Contents

Advertisement

CONVERSION KIT #466-967 FROM NG TO LP/ULPG
FOR GF900L USING SIT 845 NOVA GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Each Kit contains one LP / ULPG
Conversion Kit
GF900L + GF900C Kit# 466-967
Qty.
Part #
Description
904-345
Burner Orifi ce #53
1
918-590
Decal "Converted to LP"
1
908-528
Red Propane Label
1
918-272
Conversion to ULPG decal
1
904-529
5/32" Allen Key
1
910-037
LP Injector
1
911-137
Pilot hood holding clip
1
918-273
Red ULPG label
1
919-131
1
Instruction Sheet
IT WOULD BE BENEFICIAL TO CONVERT THE APPLIANCE PRIOR TO
THE UNIT BEING INSTALLED OR WALL FACING MATERIAL FITTED
WHICH ALLOWS ACCESS TO THE BOTTOM PANEL.
PRIOR TO CONVERSION, ENSURE UNIT HAS COOLED TO ROOM
TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY
IS TURNED OFF.
1. Remove faceplate, inner frame, glass door, front trim piece and inner
panels- see instructions in this manual.
FOLLOWING STEPS FOR GF900L:
2. Remove logs.
3. Remove burner side panels by lifting out as shown in Diagram 1.
Diagram 1 - Burner Side Panels
919-131a
Regency GF900L-1 Gas Fireplace
CONVERSION KIT #466-967 FROM NG TO ULPG
FOR GF900 USING SIT 845 NOVA GAS VALVE
IF IN DOUBT DO NOT DO THIS CONVERSION !!
4. Remove burner by removing 2 screws in locations shown below.
Diagram 2 - Burner Screw Locations
5. Remove rear log tray by removing 3 screws as shown in Diagram 3
below.
Diagram 3 - Rear Log Tray Screw Locations
FOLLOWING STEPS FOR GF900C:
6. Remove glass crystals and stones, if installed.
7. Remove 3 screws in locations shown below to remove burner tray.
Diagram 4 - Burner Tray Screw Locations
1
installation
GF900
12/06/16
31

Advertisement

Table of Contents
loading

Table of Contents