Serial Com Interface (Rs232) - ADS-tec VMT6000 Series User Manual

Hide thumbs Also See for VMT6000 Series:
Table of Contents

Advertisement

VMT6008

6.9 Serial COM Interface (RS232)

Pos : 33 /D atentec hni k/Schnitts tell en/Seriell e Schnitts tell e C OM RS232/Serielle Sc hnitts tell e C OM (RS232) für VMT 60xx @ 1 \mod_1246373571514_6.doc @ 5876 @
The serial interface is used for digital data transmission. The RS232 interface can be connected by
using a commercially available 9-pin SUB-D cable.
Note:
Pin 9 of the serial interface connector can be used for additional switching of
a 5V power supply, e.g. for operating a serial barcode scanner. The COM
+5V switch in the service slot of the device must be put in the ON position in
order to use this function. A subsequent restart of the computer might be
required in order to properly activate this function..
Pin-Number
1
2
3
4
5
6
7
8
9
Note:
This interface is not electrically isolated.
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Signal-Name
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI oder + 5V DC
(max. 1 A)
29