5.9 S
COM
ERIAL
The serial interface is used for digital data transmission. The RS232 interface can be
connected by using a commercially available 9-pin SUB-D cable.
Note:
Pin 9 of the serial interface connector can be used for additional switching of a 5V power
supply, e.g. for operating a serial barcode scanner. The COM +5V (S2) switch in the
service slot of the device must be put in the ON position in order to use this function. A
subsequent restart of the computer might be required in order to properly activate this
function.
PIN NUMBER
Note:
This interface is not electrically isolated.
Pos : 33 /D atentec hni k/Laufwer ke/Festpl atte / C ompac t Flash/Fes tpl atte C ompac t Fl ash für VMT 6008 @ 2\mod_1272446119524_6.doc @ 7722 @
28
(RS232)
INTERFACE
SIGNAL NAME
1
2
3
4
5
6
7
8
RI or + 5 V DC (1 A at max)
9
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS