INSTALLATION
When installing the head take care that the film is not deflected too much as
it goes through the head. The film may touch the fixed part of the head when
tension in not uniform. Too much deflection of the film may also degrade the
reading performance.
5.
Shuttle the film in both directions. You may find it necessary to
modify either the rotational angle or the height of the reader
head.
binding screw with the hex key tool supplied. Using a small
screwdriver, turn the adjusting screws (7) so that they make
contact with the deck plate of the telecine. This ensures that
the height can be guaranteed if the bracket needs to be moved
in the future.
2.3.1. Connecting the Reader Head to the Decoder Electronics
(Model UV-KK, UV-KK/AA, UV-KK/AR, and UV-3 Heads)
A 15 foot long extender cable is supplied to connect the universal reader
head to the model 5550 Universal Film Data Decoder. If you wish to mount
the console more than 10 feet from the telecine, 50 foot Extender cables
may be purchased.
maximum distance of 100 feet from the reader head. Plug the extender
cable into the connector on the reader head cable. Connect the other end
of the extender cable to the 15 pin D connector on the rear of the decoder
electronics.
2.3.2. Connecting the Reader Head to the Decoder Electronics
(Model EV, KK, KR, and KD Heads)
A 10 foot long extender cable is supplied to connect the universal reader
head to the model 5550 Universal Film Data Decoder. If you wish to mount
the console more than 10 feet from the telecine, 50 foot Extender cables
may be purchased.
maximum distance of 100 feet from the reader head. Plug the extender
cable into the connector on the reader head cable. Connect the other end
of the extender cable to the 8 pin mini DIN HEAD connector on the rear of
the decoder electronics.

2.3.3. Connecting Biphase from the Telecine

Although the KeyKode reader system can operate without biphase, the
best performance of the automatic reader intensity algorithms will be
obtained when biphase is connected. With the appropriate settings in the
keykode decoder, you can track changes in film density over the complete
range, making the operation of the reader system fully automatic.
Model 5550 Universal Film Data Decoder Manual
Once you are satisfied with the position, tighten the
The KeyKode Decoder may be located up to a
The KeyKode Decoder may be located up to a
Page 2-5