7700 Multi-Frame Manual
7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter
6.3.
VISTALINK

CONTROLLED PARAMETERS

®
When the MASTER jumper is set to the REMOTE position, the following parameters can be remotely
controlled through the VistaLINK
local jumper settings will override the settings configured through the VistaLINK
Parameter
Reclock Mode
Rate Mode
6.4.
VISTALINK

TRAPS

®
The following parameters can be remotely enabled and monitored through the VistaLINK
traps in the Alarm View.
Parameter
Carrier Strength Weak
EDH Error Present
Laser Not OK
Signal Not Present
7707EO-HD - 14
interface. When the MASTER jumper is set to the LOCAL position the
®
Description
Enables or disables signal reclocking.
Sets the reclocking rate to SMPTE 259M, SMPTE 292M or
SMPTE310M rates.

Table 6-2: VistaLINK

®
Description
Indicates that the optical power is approaching the optical receiver
sensitivity limits.
EDH errors present in the input signal - SD only.
Indicates deficient operation of the optical output laser. (The state of the
LASER FAULT LED)
Indicates the absence of a valid input signal. (The state of the SIGNAL
VALID LED)

Table 6-3: VistaLINK

Revision 1.5
Controlled Parameters
Traps
®
interface.
®
interface as
®