6.2.
VistaLINK
MONITORED PARAMETERS
®
The following parameters can be remotely monitored through the VistaLINK
Parameter
Card Type
Optical Power
Video Standard
Signal Not Valid
Carrier Weak
Laser Not OK
EDH Error
Reclock Mode
Rate Mode
Master Jumper
6.3.
VistaLINK
CONTROLLED PARAMETERS
®
When the MASTER jumper is set to the REMOTE position, the following parameters can be remotely
controlled through the VistaLINK
local jumper settings will override the settings configured through the VistaLINK
Parameter
Reclock Control
Rate Control
7707OO-HD SD/HD Fiber Optic Wavelength Converter
Description
Indicates either 7707OO-HD or 7707OO-HD-H card
type.
A range of values describing optical power at the
fiber input.
A range of values describing the detected video
standard.
Indicates that input signal is not valid (the state of
the SIGNAL VALID LED).
Indicates a weak signal carrier (2dB before
maximum input sensitivity) at the Fiber input (the
state of the CARRIER FAULT LED).
Indicates deficient operation of the optical output
laser (the state of the LASER FAULT LED).
The status of EDH errors present in the input signal.
The state of the RECLOCK jumper. Selects Auto
reclocking, Bypass or Forced Rate reclocking.
The state of the FORCED RATE jumper. Selects
SD, HD or SMPTE 310M reclock rates when the
FORCED RATE jumper is set to FORCED.
The state of the MASTER jumper. When in
REMOTE position the cad functions are controlled
through the VistaLINK™ interface
Table 6-1: VistaLINK
®
interface. When the MASTER jumper is set to the LOCAL position the
®
Description
Enables or disables signal reclocking.
Sets the reclocking rate to SMPTE 259M, SMPTE
292M or SMPTE310M rates when RECLOCK
jumper is set to FORCED position.
Table 6-2: VistaLINK
®
Revision 1.5
7700 MultiFrame Manual
Monitored Parameters
Controlled Parameters
interface:
®
interface.
®