b) Configuration with fireplace comburent air inlet communicating with the installation room, with fan hot air outlets connected to
the coating nozzles and natural convection hot air outlets not connected.
The fireplace can function by taking the comburent air from the installation room, connecting it with the extensible aluminium pipe (Ø120 mm
and maximum length 100 cm) to the coating (1). In this configuration it is mandatory to make an opening in the installation room (minimum
Ø200 mm) (2), communicating with the outside environment, guaranteeing a proper intake of comburent air such that it does not depressurise
the installation room.
In this configuration, the connection between the fireplace comburent air inlet to the coating and the installation room opening
are mandatory.
Make an opening (minimum 600 cm
) in the coating top part (2) to allow the vent/recovery of the heat that form inside the coating and the
2
natural convection hot air outlet (from the corresponding outlets located on the fireplace (4)) and an opening (minimum 600 cm
) in the coating
2
lower part (5) for the heating air intake (for both the fan and natural convection) from the installation room.
The two outlets of the fan hot air (6) (on the fireplace) must be connected to the nozzles (7) through an extensible aluminium pipe (8) (Ø120
mm) while the two natural convection hot air outlets (4) (on the fireplace) may be left as not connected.
The coating top and lower parts openings are mandatory.
Making an inspection opening on the coating to access the fireplace probe (9) (the inspection opening may be the same as the one
for accessing the humidifier) is mandatory
7
3
7
9
5
2
1
6
6
4
4
8
8