Jolly Mec UNIVERSALJOLLY EVO 60 4S Installation, Use And Maintenance Manual

Jolly Mec UNIVERSALJOLLY EVO 60 4S Installation, Use And Maintenance Manual

Wood burning air inset fireplace

Advertisement

UNIVERSALJOLLY EVO 4S
UNIVERSALJOLLY EVO 60 4S
UNIVERSALJOLLY EVO 68X50 4S
UNIVERSALJOLLY EVO 68X58 4S
UNIVERSALJOLLY EVO 80 4S
SUPERJOLLY EVO 60 4S
SUPERJOLLY EVO 68X50 4S
SUPERJOLLYJOLLY EVO 68X58 4S
SUPERJOLLY EVO 80 4S
I N S T A L L A T I O N ,
MAINTENANCE MANUAL
To be kept by the purchaser
SUPERJOLLY EVO 4S
Wood burning air inset fireplace
U S E
A N D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNIVERSALJOLLY EVO 60 4S and is the answer not in the manual?

Questions and answers

Summary of Contents for Jolly Mec UNIVERSALJOLLY EVO 60 4S

  • Page 1 UNIVERSALJOLLY EVO 60 4S UNIVERSALJOLLY EVO 68X50 4S UNIVERSALJOLLY EVO 68X58 4S UNIVERSALJOLLY EVO 80 4S SUPERJOLLY EVO 60 4S SUPERJOLLY EVO 68X50 4S SUPERJOLLYJOLLY EVO 68X58 4S SUPERJOLLY EVO 80 4S I N S T A L L A T I O N ,...
  • Page 2 Dear Customer, thank you for having chosen to heat and save with a Jolly Mec product. Please carefully read and keep this sheet before using the equipment. This sheet provides necessary information and suggestions on how to correctly install, use, clean and maintain the product.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS CHAP.01 PREMISES........................... 4 01.1 WARNINGS ..............................4 01.2 SYMBOLOGY ............................... 5 01.3 APPLIED STANDARDS ..........................5 01.4 USE AND STORING OF THE INSTALLATION AND MAINTENANCE MANUAL ........6 01.5 MANUFACTURER’S LIABILITY AND WARRANTY CONDITIONS ............. 6 CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS .............. 7 02.1 GENERAL CONSIDERATIONS ........................
  • Page 4: Chap.01 Premises

    CHAP.01 PREMISES 01.1 WARNINGS • Familiarity and compliance with the instructions given in this manual will ensure quick installation and correct use of the appliance. • Read the manual attentively before commencing installation, and be certain to follow the directions it contains, otherwise the war- ranty could be invalidated and the performance and safety of the appliance jeopardized. • The installation manual is an integral part of the product and must be given to the user. • It must be kept in a safe place and consulted carefully, as all of the warnings provide important information on safety during instal- lation, use and maintenance. • Incorrect installation of the appliance could cause damage and injury to people or animals, for which the manufacture cannot not be held liable. • Installation shall be performed by qualified operators in accordance with the regulations in force in the Country of installation. • The manufacturer declines any contractual or non-contractual liability for damages caused by errors in installation or use of the appliance or failure to follow the instructions contained in this manual. • All rights on the reproduction of this technical manual are owned by Jolly Mec Caminetti S.p.A. The descriptions and illustrations provided in the following publication are not binding. • reserves the right to make any modifications that may be deemed appropriate. • Jolly Mec Caminetti S.p.A This manual cannot be given to third parties for perusal without the written permission of • Jolly Mec Caminetti S.p.A • The technical directions for installation contained in this manual should be considered as basic requirements. Regulations in some countries may be more restrictive; in this instance, comply fully with the regulations prevailing in the country of installation (all laws and local bylaws must be observed when installing and using the appliance, including those referring to national and European standards).
  • Page 5: Symbology

    This point is particularly important. An important point regarding behaviour for preventing injury and damage to DANGER: materials is expressed. 01.3 APPLIED STANDARDS All JOLLY MEC products are constructed according to the following directives: • EU 305/2011 European construction products regulation. Machines. •...
  • Page 6: Use And Storing Of The Installation And Maintenance Manual

    01.5 MANUFACTURER’S LIABILITY AND WARRANTY CONDITIONS Upon the delivery of this manual, Jolly Mec S.p.A. cannot be held liable, whether civil or criminal, for accidents due to partial or total non-compliance with the specifications herein contained. The manufacturer is especially held harmless from any liability in the following cases: •...
  • Page 7: Chap.02 Accident Prevention / Safety Regulations

    CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS 02.1 GENERAL CONSIDERATIONS • The manual refers to essential aspects of the directives, regulations and dispositions on using the machine, summarising its most significant points. • General legal regulations and mandatory rules regarding injury prevention and environmental protection must be observed.
  • Page 8: Safety Regulations For Extraordinary Maintenance And Installation

    • In alarm status for failed start up, do not try to restart the appliance until the firebox has been thoroughly cleaned. • Keep the ventilation grids in the area the appliance is installed in clean conditions. • Do not use fuels that are not recommended. •...
  • Page 9: Equipment For Operators And Maintenance Personnel

    RESIDUAL RISKS Though JOLLY MEC CAMINETTI S.p.A. does everything within its power to produce its systems with the greatest competence regarding safety and consulting all the directives, laws, and regulations available, there are still, if minor, some residual risks during the phases of: •...
  • Page 10: Chap.03 Handling And Transport

    CHAP.03 HANDLING AND TRANSPORT 03.1 RECEIVING GOODS The device is delivered on a pallet in a cardboard box and protected with shrink wrap cover sheet when receiving merchandise, check that: • all packaging is intact • all of the merchandise indicated on the delivery bill has actually been delivered •...
  • Page 11: Chap.04 Ecological Regulations

    CHAP.04 ECOLOGICAL REGULATIONS 04.1 DISPOSAL OF THE MACHINE Directive 2012/19/UE (waste electrical and electronic equipment - WEEE): information for users. The crossed-out wastebasket symbol on the appliance means that at the end of its useful lifespan, the product must be disposed of separately from ordinary household wastes. The user is responsible for delivering the appliance to an appropriate collection facility at the end of its useful lifespan. Appropriate separate collection to permit recycling, treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product.
  • Page 12: Chap.05 Description

    The UNIVERSALJOLLY EVO 60 4S, UNIVERSALJOLLY EVO 68X50 4S, UNIVERSALJOLLY EVO 68X58 4S, UNIVERSALJOLLY EVO 80 4S, SUPERJOLLY EVO 60 4S, SUPERJOLLY EVO 68X50 4S, SUPERJOLLY EVO 68X58 4S, SUPERJOLLY EVO 80 4S inset fireplace are monoblock wood burning with intermittent kind of combustible charging modality;insert...
  • Page 13: Product Identification

    05.2 PRODUCT IDENTIFICATION It is COMPULSORY to indicate the product MODEL, the LOT number and SERIAL NUMBER in all communications with the Manufacturer. Identification numbers are printed on the adhesive plate located on the back of the appliance as illustrated. Appliance performance values measured during inspection tests according to the indicated reference and EC markings are also included on the plate.
  • Page 14: Chap.06 Technical Data

    All appliance tests, final inspection and fine-tuning was performed using the recommended fuels. Jolly Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of wood logs that are not recommended, as combustion parameters vary according to the quality of the fuel.
  • Page 15: Recommended Fuels

    06.2 RECOMMENDED FUELS WARNING WOOD QUALITY IS VERY IMPORTANT; PLEASE READ THIS SECTION CAREFULLY. The characteristics of fuel wood for stoves and fireplaces are defined by quality classes A1 and A2 set forth by UNI EN ISO 17225-5 standard. WOOD COMBUSTION Wood clean burning is a process that reflects the natural decomposition itself;...
  • Page 16: Components

    06.3 COMPONENTS The equipment is supplied on a pallet, in a cardboard box covered with heat shrink film and with the following additional components: • Installation, use and maintenance manual • Electronic control unit UniversalJolly EVO 4S models • Fan (410 m SuperJolly EVO 4S models Electronic control unit Rock wool matting for boiler insulation (For UniversalJolly EVO...
  • Page 17: Dimensions

    06.4 DIMENSIONS All measurements are in mm. Model UNIVERSALJOLLY EVO 60 4S 362,5 500,5 472,5 UNIVERSALJOLLY EVO 68X50 4S 442,5 500,5 472,5 UNIVERSALJOLLY EVO 68X58 4S 442,5 585,5 472,5 UNIVERSALJOLLY EVO 80 4S 562,5 585,5 472,5 SUPERJOLLY EVO 60 4S...
  • Page 18: Chap.07 Positioning And Connections For The Installer

    CHAP.07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 07.1 FLUE OR FUME EXHAUST SYSTEM The flue or fume exhaust system is a fundamental element for the proper functioning of the stove and must comply with the following general standards: EN1856-1 Chimneys. Requirements for metal chimneys - Part 1: System chimney products EN1856-2 Chimneys.
  • Page 19: Installation Room Ventilation

    The use of counter slope elements is forbidden.The flue union must have a constant section and allow soot to be collected and swept away. Changes in cross-section are only allowed at the outlet of the heat generator: the use of adaptors on the coupling with the chimney flue is prohibited.
  • Page 20: Assembly Sequence

    07.3 ASSEMBLY SEQUENCE Install the fireplace as follows: UNIVERSALJOLLY EVO 4S models SUPERJOLLY EVO 4S models Organize the air intakes as indicated at point 6. When the fireplace arrives, lie it on the floor or lift with a crane, 2A. Create the fan compartment according to the dimensions then apply the legs using the supplied screws to fasten in given in the drawings (LxHxP= 35x20x40 cm, F .1-2).
  • Page 21 For the hot air recycle into the room, it is possible to choose the following options: 1) When it is not possible to realize an opening for hot air recycle into the cladding, it is useful to take the coverings on the sides apart, by screwing off the screw: in this case the hot air fan will recycle the hot air into the room from these openings (F .
  • Page 22 7. Lower the stainless steel flue pipe all the way in the special space . 10 on the exchanger, operating from the fume exhaust or, if possible, from the outside, forcing it down with hands or using a curved iron .
  • Page 23 Mount the control unit making sure the installation point is not too hot (max 50-60°C). 12. To install the fan, remove the fire base and the lower closing plate (F . 15-20). . 15 . 16 . 17 . 18 .
  • Page 24: Installing The Cladding: Precautions

    07.4 INSTALLING THE CLADDING: PRECAUTIONS • Protection of domestic walls Installation of the fireplace near inflammable walls is only allowed if you maintain the distances indicated below, or if suitable protection is interposed. The surfaces such as the flooring, ceiling and walls of the home in the vicinity of the fireplace must be protected to prevent overheating.
  • Page 25 SAFETY DISTANCES FROM SURROUNDING FLAMMABLE MATERIALS In F . 2 are shown the safety distances from surrounding flammable materials applicable to all installation types available: Flammable Wall Flammable floor Flammable ceiling Fireplace cladding in not flammable material. Installation distances from flammable materials A Minimum air distance from inflammable side wall: 400 mm B Minimum air distance from inflammable rear wall: 150 mm...
  • Page 26: Example Of Fireplace Installed And Cladded

    07.5 EXAMPLE OF FIREPLACE INSTALLED AND CLADDED Fume exhaust Recirculation grid obligatory hood (450 cm², 100 mm from the ceiling) Flexible aluminium pipes for hot air ducting Ø 100 mm Adjustable exhaust vents for hot air (at least 2 x 80 cm²) Electronic control unit Combustion air inlet Ø100 mm with ducting pipe Air recirculation grid (450 cm²) Regulation of comburent air...
  • Page 27: Example Of Air Ducting To Other Rooms

    07.6 EXAMPLE OF AIR DUCTING TO OTHER ROOMS The air pipes must be routed to the rooms to be heated. The return of air in the fireplace room must be guaranteed from every room in which the hot air arrives, through openings under the doors or vents (see F .
  • Page 28 Installation with internal fan air intake WARNING Provide for recirculation of hot air in the room (see CHAP. 07.3, point 6, paragraph a) and b)) WARNING For ducting to several rooms fit the T connection or Y connection (optional) and connect the two top outlets as well as the ducting...
  • Page 29: Chap.08 Use And Maintenance For The User

    CHAP.08 USE AND MAINTENANCE FOR THE USER 08.1 CONTROL UNIT The Electronic Control Unit manages all functions of the device and is controlled through a display suitably designed to use the following main functions: • Fan speed in manual mode •...
  • Page 30 Dimension Comburent air record ging time 2 identical logs for a total of Lenght: 18 cm . 7) 47 minutes Universaljolly EVO 60 4S Position 2 Superjolly EVO 60 4S . 5) 1,4 kg Side: 8x8 cm . 7) 2 identical logs for a total of...
  • Page 31: Tips For The User

    08.3 TIPS FOR THE USER • When the heating system is ducted, it is mandatory to leave at least one vent open to discharge the heat generated when the device is on. • The glass door must remain closed during wood combustion; it can only be opened to add more wood. •...
  • Page 32: Routine Maintenance

    Time between one cleaning and the next is strictly tied to fuel quality. The most suitable cleaning frequency can only be established a few days after use according to the actual amount of deposited residue and may vary from recommended Jolly Mec intervals.
  • Page 33: Extraordinary Maintenance

    08.5 EXTRAORDINARY MAINTENANCE We wish to remind you that the Extraordinary Maintenance to be carried out on this type of product must be done obligatorily every year by qualified maintenance personnel, in order to maintain its functionality, efficiency and comfort. For any further queries you may have, we invite you to contact the specialised Technical Service Center through your retailer.
  • Page 34: Chap.09 Fault Diagnosis And Troubleshooting

    CHAP.09 FAULT DIAGNOSIS AND TROUBLESHOOTING 09.1 PROBLEMS WARNING In accordance with the laws in force on safety for electrical appliances, a specialised Technical Service Center or qualified personnel must obligatorily be contacted for all installation, maintenance or interventions that require access to electrical parts.
  • Page 35 NOTES...
  • Page 36 Via S.Giuseppe 2 - 24060 Telgate (Bg) Italy Tel. +39 035.83.59.211 Fax +39 035.83.59.203 www.jolly-mec.it - info@jolly-mec.it...

Table of Contents