INSTALLATION CONFIGURATIONS
Install the fireplace as follows:
Images shown are for illustration purposes only.
1) Forced air version with fan
a) Configuration with fireplace comburent air inlet communicating with the outside, with fan hot air outlets canalised and natural
convection hot air outlets not connected.
The fireplace can function by taking the comburent air from the outside, connecting it with the extensible aluminium pipe (Ø120 mm and
maximum length 100 cm) with the outside (1).
In this configuration, the fireplace comburent air inlet connection with the outside environment is mandatory.
Make an opening (minimum 600 cm
) in the coating top part (2) to allow the vent/recovery of the heat that form inside the coating and the
2
natural convection hot air outlet (of the corresponding outlets located on the fireplace (3)) and an opening (minimum 600 cm
) in the coating
2
lower part (4) for the heating air intake (for both the fan and natural convection) from the installation room.
The two outlets of the fan hot air (5) (on the fireplace) must be connected to the nozzles (6) through an extensible aluminium pipe (7) (Ø120
mm) while the two natural convection hot air outlets (3) (on the fireplace) may be left as not connected.
The coating top and lower parts openings are mandatory.
Making an inspection opening on the coating to access the fireplace probe (8) (the inspection opening may be the same as the one
for accessing the humidifier) is mandatory.