CAP.06 TECHNICAL DATA

06.1

HOMOLOGATION

Technical specifications resulting from laboratory tests conducted according to EN 13229 test methods at the CERTIFICATION institute.
Descrizione
Nominal burning output
Nominal heat power
Nominal output consumption
Efficiency at nominal output
Device mass
Device weight
Minimum flue draught at nominal heat output
Fume exhaust diameter
Average fume T at nominal heat output
CO
2
CO (13% O
)
2
NO
(13% O
)
x
2
OGC (13% O
)
2
Dusts(13% O
)
2
Minimum air distance from inflammable side wal
Minimum air distance from inflammable rear wall
Frontal air distance from inflammable material
Comburent air pipe diameter
Diameter of the hot air outlet pipe
Average heated area*
Energy efficiency class
The declared output may vary according to fuel type.
The above technical specifications were measured with certified quality WOODS. ONLY use this type of fuel as recommended later in
CHAP.06.2 - RECOMMENDED FUELS.
*According to the typology of building and insulation (Referred to the need of 55 W/m
WARNING
All appliance tests, final inspection and fine-tuning was performed using the recommended fuels.
Jolly Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of wood logs that are
not recommended, as combustion parameters vary according to the quality of the fuel.
Aerjolly 80 EVO 15
Aerjolly 80 EVO 15 CT
19,1
14,8
4,61
77,5
316
10
250
14,9
278,2
9,2
805
124
43
16
800
100
2000
120
120
99,6 - 156,6
A
and 35 W/m
3
UM
17,0
kW
14,9
kW
3,96
Kg/h
87,5
%
326
Kg
10
Pa
250
mm
10,8
g/s
198,3
°C
11,2
%
1009
mg/m
3
96
mg/m
3
38
mg/m
3
18
mg/m
3
800
mm
100
mm
2000
mm
120
mm
120
mm
100,3 - 156,7
m
2
A+
-
; room height 2,7 m).
3
15