Steep 3
Converting
Surface Burners on
Models Equipped with Dual Burners
(See Step 2 if range is equipped
with Sealed
Burners.)
1, Lift the cooktop.
2. Lift the burner
assem-
Naturaf
LP gas
=
blies
straight
up and
gas=
red or
brass
silver
set
aside
to gain
access
to surface
___
OR
@
burner spuds.
3. With a 5/16"
or
a small adjust-
able
wrench,
&
remove
each
of
the
four
spuds
on
the
_J_
surface
burner
-_
gas
inlet
tubes
and
replace them with the correct gas spuds mounted
in
a holder
at the right rear of the range,
above
the
regulator.
Natural gas spuds are brass and LP gas
spuds are red or silver.. (Mount the spuds that you
removed
from the inlet tubes back in the holder.) To
prevent
leakage,
make sure
spuds
are securely
screwed
into gas inlet tubes
4. Replace the burner assemblies
5. Keep all spuds with your range so you have them if
you move or get a different gas hook-up.
Top Burner
Natural
Gas
LP (Propane)
Orifice
Drill Size
Color
#54 (0550
Dia.)
Brass
#66 (..0330 Dia.)
Red or Silver
Convert the Oven Burner Orifices
Oven Burner
1. Remove
oven door, storage drawer
or broiler draw-
er, oven bottom
and burner
baffle (on some mod-
els)_ The lower burner orifice spud is located behind
the storage
drawer,
broiler
drawer
or kick panel
(On some models,
a metal shield must be removed
to access the orifice.)
2. To convert
to LP gas,
use a
1/2" wrench
to turn
the lower
burner
orifice
spud
clockwise.
Tighten
the spud
only until it is
snug.
To prevent
damage,
do
not overtighten
the spud,
To convert
to natural
gas,
Loosen the spud about 2 turns_
Broil Burner
(on some models)
To convert
to LP gas, use a t/2" wrench
to turn the
upper
burner
orifice
spud
clockwise.
Tighten
spud
only until it is snug with the base. To prevent damage,
do not overtighten
spud.
To convert
to natural
gas, loosen
the spud
about
2 turns
5
Convert Air Adjustment
For
LP
gas,
loosen
the
Phillips
head screw and rotate
the
shutter
to the
full
open
position
With baffle
in place,
flames
should
have
approxi-
mately
1" (2_5 cm) blue cones
and should not extend beyond
the edges of the burner baffle,.
After
30 seconds
of burner
Shutter(s)
Screw ,.-=
Air Shutter.-_
operation,
check
for flames
lifting off burner
ports.
If
lifting is observed,
gradually
reduce
air shutter
open-
ing until flames
are stabilized,
For
natural
gas,
the shutter
should
be open
!/2"
(1.3 cm) or about 3/4 of the way open_
(continued next page)
45

Advertisement

loading