Multi-Point Lock
FM7300 Series and BL7300 Series
Installation Instructions
5
Addendum (cont .)
g
Troubleshoot Latch Installation
• If the latch will not fully seat in
the door, rod or rod guide is
not aligned properly with
LBC gear. (Figure 42)
x
✓
h
Correct Rod Installation Check
• Be certain a portion of the red end of the rod can be seen in the LBC viewing window and set screw is
in the location shown. (Figure 43)
✓
1-800-727-5477 • www.sargentlock.com
Copyright © 2017, 2019, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole
or in part without the express written permission of SARGENT Manufacturing Company is prohibited.
Rod
Set Screw
x
Rod Guide
REPEAT:
Step 6E to align.
Rod Guide
Figure 42
✓
Viewing
Window
x
x
Figure 43
20
Misaligned
Rod Guide
REPEAT:
Step 6E to align.
✓
Aligned
x
A8220D 10/19