Raytheon Speed Queen AWM190 Service Manual page 72

Table of Contents

Advertisement

A
WARNING~~~~~~~~~~~~~~~~~~~~~~~~~~-.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels
removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
woo3
EMERSON MOTOR WINDINGS
NOTE: Refer to SECTION VII for Internal Wiring of Washer Motor Switch.
START
WINDING
HIGH SPEED
WINDING
LOW SPEED
WINDING
AWARNING - - - - - - - - - - - .
Disconnect electric power to washer
before performing the following
steps, or when replacing switch.
4
-
5 OHMS BETWEEN
BROWN WIRE AND RED
WIRE.
YES
1
-
2 OHMS BETWEEN
BLUE WIRE
AND YELLOW
WIRE.
YES
1
-
2 OHMS BETWEEN
YELLOW WIRE AND VIOLET
WIRE.
YES
INOPERATIVE START
WINDING.
REPLACE
MOTOR.
INOPERATIVE HIGH SPEED
WINDING.
REPLACE
MOTOR.
INOPERATIVE LOW SPEED
WINDING
.
REPLACE MOTOR.
[
J
CONTINUITY EXISTS BETWEEN
PROTECTOR
.__
·
____
Y_E_L_Lo..,...w_w_1R_E _ _ ___.
_
AND WHITE
WIRE.
INOPERATIVE COMMON LEAD.
REPLACE MOTOR.
YES
ALL MOTOR WINDINGS
CHECK OK.
INDICATE WHETHER YES, MOTOR PASSED
THIS TEST OR,
NO
IT FAILED THIS TEST
[!:}YES
[!)NO
Washer Motor Failure
MOTOR SWITCH
MOTOR WINDINGS
Start Terminals:
D
A.
Start Winding:
D
B.
High Speed Winding:
High Speed Terminals:
D
c.
Low Speed Winding:
D
0.
Protector/Common Lead:
Low Speed Terminals:
D
E.
D
F.
70
D
G.
D
H.
D
I.
D
J.
36793

Advertisement

Table of Contents
loading

Table of Contents