A
WARNING~~~~~~~~~~~~~~~~~~~~~~~~~---.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels
removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
22.
HUB AND SEAL
KIT
ASSEMBLY
IMPORTANT:
If
water is present in washtub,
spin
and pump out before removing drive bell.
a.
Remove two screws from bottom edge of
front
panel,
Figure 21
.
b.
Pull
bottom of panel away from washer until
hold-down clips (located on top flange of
panel)
disengage from slots in cabinet
top,
Figure 21
.
c. Open loading door.
d.
Remove agitator by placing two agitator
hooks, No.
254P4P,
under bottom edge of
agitator,
Figure
13.
IMPORTANT:
Hooks should be
positioned
180
degrees of each other, and must be placed
under
agitator vanes for
greater stability.
If hooks are
placed
between vane
area,
damage to agitator
may
occur.
e. Using a rocking motion (back and forth)
carefully lift agitator off drive bell.
f. Hinge cabinet top or
remove,
paragraph
18.
g. Unhook pressure hose and grommet from
retainer clip located on left rear edge of outer
tub
cover,
Figure
37.
h. Loosen hose clamp and remove filler hose
from outer tub
cover,
Figure 37.
NOTE: When reinstalling
filler
hose,
white line
on
hose
must be aligned with line located on
top
side
of outer tub cover,
Figure
37.
Tub Cover and Gasket:
1 . There are eight tub cover hold-down tabs
which snap over the outer tub
flange.
Using special tub cover tool, Part No.
273P4, insert two prongs of tool
underneath each side of tandem
tabs,
Figure
37.
Tilt
tool toward
center of tub
cover and at the same time lift upward on
cover to unsnap hold-down tabs from outer
tub
flange.
One by
one,
disengage each of
the eight hold-down
tabs
from outer tub
flange and remove cover.
2.
Lift cover off outer tub and set beside
washer cabinet.
IMPORTANT: When installing outer
tub
cover,
always use
a
new cover gasket.
NOTE: Clean and remove any
foreign
material in
gasket groove of outer
tub
cover and outer
tub
36793
33
3.
Starting at the positioning pin located
between the
two
bleach funnel outlet
tabs,
lay gasket into gasket groove of tub
cover,
Figure 38.
4.
Using your fingers, press gasket down into
gasket groove of tub cover. Avoid pressing
gasket past ends of hold-down tabs.
IMPORT
ANT:
Care must
be
taken
not to
twist or
bunch gasket
in
any
one
area
to
avoid
leaks
after
assembly.
5.
Install
gasket past ends of hold-down tabs
to bottom of gasket groove using semi-
curled end of tub cover tool Part No.
273P4.
NOTE:
Tub
cover tool
Part No. 273P4 is
designed
to spread
open
hold-down tabs to prevent tearing
of gasket
during installation.
6. With tub cover tilted at approximately a 45
degree
angle,
insert the positioning pin into
notch on outer tub
flange,
Figure 39
NOTE: The two
bleach
funnel outlet
tabs
must be
angled
downtward
toward inside wall of outer tub
for
proper dispensing of
bleach.
7
.
Lower cover and push down firmly on top
of hold-down tabs next to positioning pin
until tabs snap over edge of outer tub
flange.
8.
Cross over to opposite side of tub cover
and push down firmly on top of hold-down
tabs until tabs snap over edge of outer tub
flange.
Continue with this criss-cross
pattern
,
until tub cover is fully
seated.
Visually check each tab area again to
ensure cover is seated.
9. Check whether or not bleach drain tabs are
in the down position by looking through the
square holes in bleach funnel area of tub
cover.
If
tabs
are not down
,
a small
screwdriver can be inserted down through
holes in bleach funnel area to straighten
tabs
.

Advertisement