WARNING~~~~~~~~~~~~~~~~~~~~~~~~~~--,
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
w
oo3
8. PRESSURE SWITCH
a. Remove
six screws
(3 on top
and
3 at lower
front) holding hood
assembly
to
control
hood
rear panel and
cabinet
top.
b.
Pivot
hood assembly
forward
on cabinet
top.
c.
Disconnect wires from pressure
switch.
d.
Refer to Figures 5 through 8
for switch
removal.
NOTE: Refer to appropriate wiring diagram when
rewiring
switch.
IMPORTANT: Before connecting hose to pressure
switch, blow air through pressure hose to remove
any condensation that may have accumulated
in
the
hose.
9. GRAPHIC PANEL
(Refer to Figures
5
through 8)
a. Unscrew timer
knob
from timer shaft (right
hand thread)
,
then remove timer
knob skirt.
b.
Pu!I knob
off
switch shaft.
c. Remove six screws (3
on top
and 3 at
lower
front)
holding
hood
assembly to control hood
rear panel
and cabinet
top.
d.
Pivot hood
assembly forward on cabinet
top.
e.
Disconnect
wires from component
parts
and
carefully remove components from control
hood
assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
f. Bend tabs on graphic panel
(located
inside of control hood) straight out toward
rear of hood.
g. Carefully remove graphic panel off front of
control hood.
12
10. LOADING DOOR
a. Open loading door, Figure 11.
b. Remove two
screws
holding left hinge to
door
and remove hinge and
gasket,
Figure 11.
c.
With loading door raised to
vertical
position,
swing left
side
of door toward front of washer.
Figure 12, procedure
one.
d. Rotate loading door so door is upside
down,
Figure
12,
procedure
two.
e.
Carefully remove loading
door,
right hinge
and
bushing from
cabinet
top,
Figure
12,
procedure three.
NOTE: Reverse procedure when installing door.
HINGE
(Left)
HINGE
(Right)
W216SE
1A
Figure 11
HINGE
ATTACHING
SCREWS
36793