A
WARNING~~~~~~~~~~~~~~~~~~~~~~~~~~-.
To reduce the
risk
of electric shock, fire, explosion, serious injury or death:
• Disconnect
electric
power to the washer before servicing.
Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must
be
reconnected
to
ensure
that
the washer is properly grounded.
w
003
41.
NO AGITATION
POSSIBLE CAUSE
• •
••
Inoperative timer.
Timer is
designed to pause
Test timer
and
replace if inoperative.
(SOAK) during DELICATE
cycle.
Motor will not run.
Refer to SECTION V to check
switch and
windings.
No Delicate
cycle agitate.
Refer to SECTION
V
to
check
low speed
switch and
windings.
Inoperative
pressure switch.
Test
switch and replace if inoperative.
Broken, loose,
or
incorrect
wiring.
Refer to
appropriate wiring
diagram.
Loose
or
broken drive belt.
Adjust
or
replace
belt.
Inoperative transmission
assembly.
Repair
or
replace
transmission
assembly.
Sheared
motor pulley
roll
pin.
Remove drive motor
and replace roll
pin
and
any other
damaged
parts.
Motor overload protector has cycled.
Wait two
or
three
minutes
for
overload protector
to
reset. If
protector
cycles
repeatedly
,
refer
to
paragraph 43.
Bind in pump.
Replace pump.
Loading door is open or door switch is
inoperative.
Close
door or test
switch and
replace
if
inoperative.
42.
CONSTANT AGITATION
POSSIBLE CAUSE
TO CORRECT
Inoperative
timer.
Test
timer and replace
if inoperative.
Shorted or incorrect
wiring.
Refer to appropriate wiring
Diagram.
Inoperative transmission
assembly.
Repair or replace transmission
assembly.