A.
WARNING---------------------------~
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground w ires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
wooo
16.
MOTOR DRIVE PULLEY
a. Remove two screws from bottom edge
of
front panel, Figure 21.
b.
Pull
bottom of panel away from washer until
hold-down cl ips
(located
on top flange of
panel) disengage from slots in
cabinet
top.
IMPORTANT:
There will always be some water
that will remain in outer
tub, therefore,
before
removing hoses
from pump,
hoses
must
be
pinched off or drained to prevent water spillage.
c. Loosen hose clamps and remove hoses from
pump
assembly,
Figure 23.
d.
Unhook idler
spring
and helper
spring
from
idler
lever, Figure 25.
20
IMPORTANT:
Use care when removing
idler
spring and helper
spring.
If idler spring or
helper
spring are
overstretched, washer
operation will be
affected.
e.
Reach
in and around right side
of motor
and
run belt
off
right
side
of
large drive pulley,
Figure 22.
f. Disconnect wire
harness
from
motor
switch
by pressing down on locking tab
on top
of
connection block and
at the same
time
pull
connection
block
away from motor
switch,
Figure
23.
g.
Remove four
screws holding motor assembly
to washer
base,
Figure
23,
then
lift
complete
assembly out
of
washer.
h. Lay motor assembly
on
its
side.
NOTE:
To remove
pulley,
support
motor
shaft
(to
prevent bending
shaft)
and
drive
out pulley
roll
pin,
Figure
25.
36793