WARNING~~~~~~~~~~~~~~~~~~~~~~~~~~-,
To reduce the risk of electric shock, fire, explosion, serious injury or
death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed •
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer
is
properly grounded.
woo
3
TUB
COVER
FILLER
HOSE
HOLD-DOWN
TABS
Figure 37
HOSE
CLAMP
LINE ON
COVER
273P4
TUB COVER
TOOL
21
.
WASHTUB AND CLOTHES GUARD
NOTE: When
installing
filler hose, white line on
hose must be aligned with line located on top
side
of outer tub cover,
Figure 37.
a
.
Open loading door.
b.
Remove
agitator by placing two agitator
hooks,
No.
254P4P, under bottom edge of
agitator,
Figure
13.
IMPORTANT: Hooks should be positioned
180
degrees
of
each other, and must be placed under
agitator
vane
for
greater stability.
If
hooks are
placed between vane area, agitator damage may
occur.
36793
c.
Using a rocking motion (back and forth)
carefully lift agitator off drive bell.
d.
Hinge cabinet top or remove
,
paragraph 18.
e. Loosen hose clamp and remove filler hose
from outer tub
cover,
Figure 37.
29
f.
Unhook pressure hose and grommet from
retainer clip located on left rear edge of
outer tub
cover,
Figure 37.
g
.
There are eight tub cover hold-down tabs
which snap over outer tub flange. Using
special tub cover tool, Part No. 273P4, insert
two prongs of tool underneath each side of
tandem tabs, Figure 37. Tilt tool
toward
center of tub cover and at same
time
lift
upward on cover to unsnap hold-down tabs
from outer tub
flange.
One by
one,
disengage
each of the eight hold-down tabs from outer
tub flange and
remove cover.