6.4.4. Reserve capacity (RC) or (SF)
Determine the reserve capacity in litre or in percentage.
H
Adjust the reserve capacity with
I
Press
to validate the selection and advance to the next parameter.
6.4.5. Current day of the week (CD)
Determine the day of regeneration.
Note
Appears only if the softener is set to "weekly time clock".
Note
1 for Monday, 2 for Tuesday, 3 for Wednesday, 4 for Thursday, 5 for Friday, 6 for Saturday
and 7 for Sunday.
J
Adjust the day of the week with
K
Press
to validate the selection and exit the basic programming mode.
6.5.
Master programming mode
Note
As soon as programming mode is entered, all parameters can be displayed or set to suit the
needs. Depending on the current programming, some functions will not be displayed or will
not be changeable.
Note
If no button is pressed for 5 minutes in the Programming mode (basic or master mode), or
if there is a power failure, the controller returns to Service mode and changes made are not
saved.
Note
Menus are displayed in a defined and incremental order.
A
Mandatory
In order to save the new settings in the programming mode, it is necessary to go through all
the parameters.
6.5.1. Master programming mode chart
Parameter
DF
Display format
Ref. MKT-IM-020 / B - 08.06.2018
Installer Manual Fleck 9000 - SXT - Programming
and
.
and
.
Options
Definition
GAL
US units
Ltr
Metric units
Note