Hygiene Measures - Pentair FLECK 9000 SXT Installer Manual

Hide thumbs Also See for FLECK 9000 SXT:
Table of Contents

Advertisement

Assembly
Assemble only with components which are in accordance with drinking water standards;
after installation and before use, perform one or more manual regenerations in order to clean
the media bed. During such operations, do not use the water for human consumption. Perform a
disinfection of the system in the case of installations for treatment of drinking water for human
use.
Note
This operation must be repeated in the case of ordinary and extraordinary maintenance. It
should also be repeated whenever the system remains idle for a significant time.
Note
Valid only for Italy: In case of equipment used in accordance with the DM25, apply all the
signs and obligations arising from the DM25.

2.4.2. Hygiene measures

Disinfection
The materials used for the construction of our products meet the standards for use with potable
water; the manufacturing processes are also geared to preserving these criteria. However, the
process of production, distribution, assembly and installation, may create conditions of bacterial
proliferation, which may lead to odor problems and water contamination;
it is therefore strongly recommended to sanitize the products. See 7.2. Sanitization, page 62;
maximum cleanliness is recommended during the assembly and installation;
for disinfection, use Sodium or Calcium Hypochlorite and perform a manual regeneration.
Ref. MKT-IM-020 / B - 08.06.2018
Installer Manual Fleck 9000 - SXT - Safety
13 / 108

Advertisement

Table of Contents
loading

Table of Contents