Installer Manual Fleck 9000 - SXT - Troubleshooting

10.2.2. Motor run-ON error/cycle sense error

Note
An undesired microswitch state change occurred.
A
Unplug the unit and plug back in. Allow the controller to attempt to find
position again.
B
If the unit doesn't find position, unplug, open the cover (see "Controller
replacement", page 67) and examine the power head.
C
Verify the microswitch is in place with wires connected to the circuit board.
D
Enter master programming mode.
E
Verify that the valve type and system type are set correctly with regard to
the unit itself.
F
Step the unit to a manual regeneration.
G
Verify that it functions correctly.
H
If the error reoccurs, unplug the unit.
I
Put it into bypass.
J
Contact dealer.

10.2.3. Regeneration failure

Note
The system has not regenerated for more than 99 days or 7 days if the controller type has
been set to day of week.
A
Perform a manual regeneration to reset the error code.
B
If the system is metered, verify that it is measuring flow by running service
water and watching for the flow indicator on the display.
C
If the unit doesn't measure flow, verify that the meter is working properly
and its cable is well connected.
D
Enter master programming mode.
E
Verify that the unit is configured properly.
F
Check that system capacity has been selected.
G
Check that day override is set properly.
H
Check that meter is identified correctly.
I
If the unit is configured as a day of week system, verify that at least one day
is set ON.
J
Correct the setting as necessary.