EWM Tetrix DC Smart 2.0 T4.05 Operating Instructions Manual page 50

Control
Table of Contents

Advertisement

Functional characteristics
Machine configuration menu
Display
50
Setting/selection
Alternative welding start – tapping start
Available from torch mode 11 (welding stop by tapping remains active).
------- Function enabled (ex works)
------- Function disabled
Up/down speed > see 5.1.8.3 chapter
Increase value > rapid current change
Decrease value > slow current change
Current jump > see 5.1.8.4 chapter
Current jump setting in ampere
Machine configuration
Settings for machine functions and parameter display
Absolute value setting (ignition, secondary, end and hot start cur-
rent) > see 4.2.1 chapter
------- Welding current setting, absolute
------- Welding current setting, as a percentage of the main current (ex works)
Non-latched operation (version C) > see 5.1.4.6 chapter
------- Function enabled
------- Function disabled (ex works)
Welding current actual value display > see 4.2 chapter
------- Actual value display
------- Nominal value display
Pulsed TIG welding (thermic) in the upslope and downslope pha-
ses > see 5.1.5.1 chapter
------- Function enabled (ex works)
------- Function disabled
TIG antistick > see 5.1.7 chapter
------- function active (factory setting).
------- function inactive.
Show warnings > see 6.1 chapter
------- Function disabled (ex works)
------- Function enabled
Setting the system of units
------- Units of length in mm, m/min. (metric system)
------- Unit of length in inches, ipm (imperial system)
Machine configuration (second part)
Settings for machine functions and parameter display
RTF start ramp > see 5.1.9.1 chapter
------- Welding current rises to the specified main current level in a ramp function (ex
works)
------- Welding current immediately jumps to the specified main current level
RTF response > see 5.1.9.2 chapter
------- Linear response
------- Logarithmic responsive (ex works)
spotmatic operating mode > see 5.1.4.5 chapter
Ignition by contact with the workpiece
------- Function enabled (ex works)
------- Function disabled
Spot time setting > see 5.1.4.5 chapter
------- Short spot time, setting range 5 ms to 999 ms, increments of 1 ms (ex works)
------- Long spot time, setting range 0.01 s to 20.0 s, increments of 10 ms (ex works)
099-00T405-EW501
14.02.2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tetrix DC Smart 2.0 T4.05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tetrix dc smart 2.0 t4.11Tetrix dc smart 2.0 t4.13

Table of Contents