Sequence:
Press torch trigger and hold down.
The gas pre-flow time elapses.
HF start pulses jump from the electrode to the workpiece. The arc ignites.
The welding current flows and immediately assumes the value of the start current
HF switches off.
The welding current ramps up to the main current
The process ends when the set spotArc.time elapses or by releasing the torch trigger. With the spotArc
function enabled, the Automatic Puls pulse variant is activated as well. If required, the function can be
disabled by pressing the pulsed welding push-button.
099-00T405-EW501
14.02.2022
Functional characteristics
Figure 5-9
(AMP) within the set up-slope time