5.1.11 Aligning The Cable Resistance - EWM Tetrix DC Smart 2.0 T4.05 Operating Instructions Manual

Control
Table of Contents

Advertisement

Display

5.1.11 Aligning the cable resistance

To ensure optimum welding properties, the electric cable resistance should be aligned again whenever an
accessory component such as the welding torch or the intermediate hose package (AW) has been chan-
ged. The resistance value of the cables can be set directly or can be aligned by the power source. In the
delivery state the cable resistance is set to the optimum values. To optimise the welding properties for
other cable lengths, an alignment process (voltage correction) is necessary.
1
0
2
3
4
0
099-00T405-EW501
14.02.2022
Setting/selection
End current time (duration of end current)
Parameter activArc > see 5.1.6 chapter
Setting the intensity
Ignition type (TIG)
-------HF start active (ex works)
-------Lift arc ignition active
l
+
+
+
l
Functional characteristics
RT50 7POL
B
A
Figure 5-24
TIG welding
43

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tetrix DC Smart 2.0 T4.05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tetrix dc smart 2.0 t4.11Tetrix dc smart 2.0 t4.13

Table of Contents