Pulse balance
Pulse frequency
5.1.5.1
Pulsed welding in the upslope and downslope phases
The pulse function can also be deactivated if necessary during the up-slope and down-slope
phases (parameter
5.1.5.2
Automated pulses
The automated pulsing pulse variant is only activated for DC welding in combination with the spotArc ope-
rating mode. The current-dependent pulse frequency and balance create vibrations in the weld pool that
have a positive effect on the gap bridging. The required pulse parameters are automatically defined by
the machine control. If required, the function can be disabled by pressing the pulsed welding push-button.
099-00T405-EW501
14.02.2022
Figure 5-16
Figure 5-17
) > see 5.6 chapter.
Figure 5-18
Functional characteristics
TIG welding
31