Internal Alarms/Warnings
E-Code
Displayed Alarm
4904
Engine Fuel Valve
1 Position
4907
Engine Fuel Valve
1 Position
4915
Engine Fuel Valve
1 Position
4917
Engine Fuel Valve
1 Position
5003
Engine Charge Air
Cooler 1 Bypass
5004
Engine Charge Air
Cooler 1 Bypass
5100
Engine Speed
5101
Engine Speed
5102
Engine Speed
5107
Engine Speed
5115
Engine Speed
5117
Engine Speed
36
Alarm/Warning
Description
Fuel Mixer—Voltage below normal range; shorted to low source; open circuit.
A
Fuel Mixer—Mechanical system not responding correctly.
A
W
Fuel Mixer—Data valid but above normal operating range; least severe level.
W
Fuel Mixer—Data valid but below normal operating range; least severe level.
A
CAC—Voltage above normal range; shorted to high source.
A
CAC—Voltage below normal range; shorted to low source; open circuit.
A
RPM High—Data valid but above normal operating range; high severe level.
RPM Low—Data valid but below normal operating range; high severe level.
A
A
RPM Fault—Data erratic, intermittent, or incorrect.
RPM Fault—Mechanical system not responding correctly.
A
W
RPM High—Data valid but above normal operating range; least severe level.
RPM Low—Data valid but below normal operating range; least severe level.
W
Technical Manual Power Zone 410 Controller

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Zone 410 and is the answer not in the manual?

Questions and answers

Marty
March 17, 2025

How to reset after it codes

User image 67d8704e238bd
1 comments:
Mr. Anderson
March 17, 2025

To reset the Generac Power Systems Power Zone 410 after it shows a code, follow these steps:

1. Identify the Code – Check the displayed fault code to understand the issue.
2. Resolve the Issue – Address the underlying problem, such as fuel pressure issues or internal faults.
3. Reboot the Controller – Some faults, like watchdog timeouts or exceptions, trigger an automatic reboot.
4. Manually Reset if Needed – If the controller does not reset automatically, power cycle the system by turning it off and on.
5. Re-enter Activation Code – If prompted, enter the correct activation code within three attempts.
6. System Update – If the issue persists due to a software problem, complete the system update process.

If the issue remains unresolved, contact an IASD (Independent Authorized Service Dealer).

This answer is automatically generated

Table of Contents