DEMAG ZBA Assembly Instructions Manual page 52

Brake motors
Table of Contents

Advertisement

Motor for one line voltage, pole-changing, separate windings
Common power supply to motor and brake
N0
1U
1V
1L2
1L3
2U
2V
2W
1U
A
1V
1W
1L1
Motor supplied with:
Motor winding connected as in connection diagram (1U and 2U connected to one terminal).
Brake connected to terminals 1 and 2 of the GE module.
SE module connected to terminals 3 and 4 of the GE module.
SE module connected with intermediate terminal A and the motor winding via terminal 1U 2U.
GE module connected with the motor winding via intermediate terminal A and terminal N10.
038 422 84
Motor for one line voltage, pole-changing, separate windings
Common power supply to motor and brake
N0
1U
1V
1W
1L2*
2U
2V
1U
A
1V
1L1
1L2
1L3
1L1*
Motor supplied with:
Motor winding connected as in connection diagram (1U and 2U connected to one
terminal)
Brake connected to terminals 1 and 2 of the GF module.
GF module connected with the motor winding and intermediate terminal A as in the
connection diagram.
038 423 84
52
N10
2U
2W
1W
2V
N10
SE
~ ~
N0
BK
BK
WH GY
2U
A
1U
4
3
GE
N10
2U
2V
2W
1L3*
2W
N10
1W
N0
7
6
N0
BD1
BD2
GE
+
~ ~
-
7
6
5
4
3
2
1
WH GY
A
BD2
BD1
N10
SE
03842284.eps
BD1
BD2
GF
+
-
4
3
2
1
5
BD2
BD1
1U
A
N10
2U
03842384.eps
2U, 2V, 2W
for high speed
Only the high speed winding is used.
Switch-off in the DC circuit
dependent on motor current
i
Not suitable for inverter operation.
A
= Intermediate terminal
* = Supply to high-speed winding via external
switch-over.
1U, 1V, 1W
for low speed
2U, 2V, 2W
for high speed
Switch-off in the DC circuit
dependent on motor current
i
Not suitable for inverter operation.
A
= Intermediate terminal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZbeZbpZbf

Table of Contents