DEMAG ZBA Assembly Instructions Manual page 34

Brake motors
Table of Contents

Advertisement

Motor for one line voltage or dual voltage
motor (1:√3)
U2
V2
U1
V1
Y
W2
U2
V2
U1
V1
W1
1L1
1L2
1L3
Motor supplied with:
Jumper parts to connect the motor winding with Y or ∆ connection enclosed.
Brake connected to terminals 1 and 2 of the GE module.
VE module connected to terminals 1, 3 and 4 of the GE module.
Important: The brake will not function without a separate power supply to
terminals 5 and 6 of the GE module.
037 876 84
Dual voltage motor 1:2
U2
V2
W2
U1
V1
W1
YY
U2
V2
W2
U5
V5
W5
U1
V1
W1
1L1
1L2
1L3
Motor supplied with:
Motor winding connected with Y connection
Jumper parts to connect the motor winding with YY connection enclosed.
Brake connected to terminals 1 and 2 of the GE module.
VE module connected to terminals 1, 3 and 4 of the GE module.
Important: The brake will not function without a separate power supply to
terminals 5 and 6 of the GE module.
037 881 84
34
W2
X1
RD
VE+ GE1 BD1
W1
Δ
W2
U2
V2
VE
- +
U1
V1
W1
WH
BU
RD
1L1
1L2
1L3
4
3
X1
GE
X1
RD
VE+ GE1 BD1
U5
V5
W5
Y
U2
V2
W2
U5
V5
W5
VE
- +
U1
V1
W1
WH
BU
RD
1L1
1L2
1L3
4
3 X1
GE
BD1
BD2
GE
- +
~ ~
7
6
5
4
3
2
1
WH
BU
2L2 2L1
X1
BD2
VE
03787644.eps
BD1
BD2
GE
+
~ ~
-
7
6
5
4
3
2
1
WH
BU
2L2 2L1
BD2
X1
VE
03788184.eps
Y
high voltage
low voltage
Voltage-dependent switch-off in the
DC circuit
Separate power supply to brake
For inverter operation, connect the motor with Y or ∆
connection according to the inverter settings.
YY low voltage
Y
high voltage
Voltage-dependent switch-off in the
DC circuit
Separate power supply to brake
For inverter operation, connect the motor with YY or
Y connection according to the inverter settings.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZbeZbpZbf

Table of Contents