Motor for one line voltage
A: Common power supply to motor and brake
B: Separate power supply to brake
U2
V2
U1
V1
Y
W2
U2
V2
U1
V1
W1
1L1
1L2
1L3
Motor supplied with:
•
Jumper parts to connect the motor winding with Y connection enclosed.
•
Brake connected to terminals 1 and 2 of the GS module.
•
SE module connected to terminals 3 and 4 of the GS module.
•
SE module connected with the motor winding according to variant Y.
•
Line operation:
•
Separate power supply to the brake:
037 884 84
Motor for one line voltage, pole-changing, separate windings
* = Supply to high-speed winding via external switch-over
1U, 1V, 1W
2U, 2V, 2W
1U
1V
1W
2U
1U
1L1
1L1*
Motor supplied with:
•
Jumper parts to connect the motor winding enclosed.
•
Brake connected to terminals 1 and 2 of the GS module.
•
Jumper between terminals 3 and 4 of the GS module.
•
Line operation:
(1U connected to terminal 6; terminal 5 free).
Important:
The brake will not function without an external power supply to
terminal 5 of the GS module.
•
Separate power supply to the brake:
037 886 84
36
W2
W1
SE
~ ~
7
BK
BK
WH GY
Y
U2
V2
A:
4
3
B:
GS
GS module connected with the motor winding according to variant A.
–
GS module not connected to the motor winding.
–
Power supply by the customer according to variant B.
for low speed
for high speed
2U
2V
2W
BD1
1L2*
1L3*
2V
2W
~ ~
1V
1W
7
6
1L2
1L3
A:
1U
2L2
B:
GS module connected with the motor winding according to variant A
– GS module not connected to the motor winding.
– Power supply by the customer according to variant B.
BD1
BD2
GS
+
~ ~
-
6
5
4
3
2
1
WH
GY
BD2
BD1
U2 U1
2L2 2L1
SE
03788484.eps
BD2
GS
- +
5
4
3
2
1
BD2
BD1
1L2
S
ext.
2L1
03788684.eps
The brake coil is rated for the
phase voltage.
Switch-off in the DC circuit
dependent on motor current
i
Not suitable for inverter operation.
A: Common power supply to motor and brake
i
Not suitable for inverter operation.
B: Separate power supply to brake
Switch-off in the DC circuit
•
Remove jumper between terminals 3 and 4.
•
Connect a contactor between terminals 3 and 4.
Switch-off in the AC circuit
•
Jumper between terminals 3 and 4.
•
Contactor contact in the supply line behind
terminal 5.