DEMAG ZBA Assembly Instructions Manual page 45

Brake motors
Table of Contents

Advertisement

Motor for one line voltage
U2
V2
U1
V1
Y
W2
U2
V2
W2
U1
V1
W1
U1
1L1
1L2
1L3
1L1
Motor supplied with:
Jumper parts to connect the motor winding with Y or ∆ connection enclosed.
Brake connected to terminals 1 and 2 of the GS module.
Jumper between terminals 3 and 4 of the GS module.
Line operation:
Inverter operation or separate power supply to the brake:
038 006 84
Motor for one line voltage or dual voltage
motor (1:√3)
U2
V2
W2
U1
V1
W1
Y
Δ
W2
U2
V2
W2
U2
U1
V1
W1
U1
V1
1L1
1L2
1L3
1L1
1L2
Motor supplied with:
Jumper parts to connect the motor winding with Y or ∆ connection enclosed.
Brake connected to terminals 1 and 2 of the GS module.
VE module connected to terminals 1, 3 and 4 of the GS module.
Important: The brake will not function without a separate power supply to
terminals 5, 6 and 7 of the GS module.
038 007 84
W2
W1
BD1
Δ
U2
V2
~
~
~
V1
W1
7
6
5
1L2
1L3
A:
U1
W1
V1
B:
2L3
2L2
2L1
GS module connected with the motor winding according to variant A.
– GS module not connected to the motor winding.
– Power supply by the customer according to variant B.
X1
RD
VE+ GS1 BD1
V2
VE
~
- +
W1
7
WH
BU
RD
1L3
2L3
4
3
X1
GS
BD2
GS
-
+
4
3
2
1
BD2
BD1
S
03800684.eps
BD1
BD2
GS
~
~
-
+
6
5
4
3
2
1
WH
BU
2L2
2L1
BD2
X1
VE
03800784.eps
A: Common power supply to motor and brake
i
Not suitable for inverter operation.
B: Separate power supply to brake
For inverter operation, connect the motor with Y
or ∆ connection according to the inverter settings
Switch-off in the DC circuit
Remove jumper between terminals 3 and 4.
Connect a contactor between terminals 3 and
4.
Switch-off in the AC circuit
Jumper between terminals 3 and 4.
Contactor contacts in the supply lines behind
terminals 5 and 6.
Motor current switch-off
Jumper between terminals 3 and 4
→ not possible for separate power supply to
the brake.
Y
high voltage
low voltage
Separate power supply to brake
For inverter operation, connect the motor with Y or
∆ connection according to the inverter settings.
Voltage-dependent switch-
off in the DC circuit
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZbeZbpZbf

Table of Contents