Summary of Contents for LOGICDATA DMIclassic Series

  • Page 1 DOCUMENT VERSION 1.0 | SEPTEMBER 2023 DMIclassic Family Operating Manual...
  • Page 2 DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 2 DMIclassic Family - Operating Manual Document Version 1.0 / September 2023 This document was originally published in English. LOGICDATA Electronic & Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone: +43 (0) 3462 51 98 0...
  • Page 3: Table Of Contents

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 3 CONTENTS General Information Other Applicable Documents Copyright Royalty-Free Use of Images and Text Trademarks Safety Target Audience General Safety Regulations Intended Use Reasonably Foreseeable Misuse Explanation of Symbols and Signal Words Liability Residual Risks Skilled Persons Notes for Resellers...
  • Page 4 DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 4 Process Completing Assembly System Information DMIclassic B DMIclassic C Operation Adjusting the Table Top Height Saving a Memory Position (DMIclassic C Only) Adjusting the Table to a Memory Position (DMIclassic C Only) Changing the Height Display (cm/inch, Dmiclassic C Only) Additional Information...
  • Page 5: General Information

    LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind. Contact LOGICDATA to obtain text or images in an editable format (documentation@logicdata.net).
  • Page 6: Safety

    • Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment • Do not convert or modify any components without written approval from LOGICDATA • In the event of malfunction or damage, faulty components must be replaced immediately •...
  • Page 7: Explanation Of Symbols And Signal Words

    2.6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by: • Improper product use • Disregard of the documentation •...
  • Page 8: Residual Risks

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 8 2.7 RESIDUAL RISKS Residual risks are the risks that remain after all relevant safety standards have been complied with. These have been evaluated in the form of a risk assessment. Residual risks associated with the installation of the DMIclassic Family handsets are listed here and throughout this Operating Manual.
  • Page 9: Skilled Persons

    • Has read and understood all documentation relevant to the Handset 2.9 NOTES FOR RESELLERS Resellers are companies that purchase LOGICDATA products for installation in their own products. INFO For reasons of EU conformity and product safety, Resellers should provide end users...
  • Page 10: Scope Of Delivery

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 10 3 SCOPE OF DELIVERY The standard scope of delivery for Handsets in the DMIclassic Family consists of the Handset, its preattached cable (and 3 mounting screws only in case DMIclassic C). All other components necessary for installing the Handset must be supplied separately by the reseller.
  • Page 11: Product

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 11 5 PRODUCT The DMIclassic Family of Handsets consists of two products: DMIclassic B and DMIclassic C. In general, operation and assembly of both handsets are similar with some differences that will be pointed out within this manual further on.
  • Page 12: Dmiclassic C

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 12 5.1.2 DMICLASSIC C Memory Position Keys Mounting Points UP / DOWN Keys SAVE Key Display Mounting Plate (for sliding mechanism) Fig. 2: Product features, DMIclassic C 5.1.2.1 ABOUT THE SLIDING MECHANISM The Sliding Mechanism is a feature of DMIclassic C that allows the handset to be stowed under the table, during transportation or when it is not being used.
  • Page 13: Dimensions

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 13 5.2 DIMENSIONS 5.2.1 DMICLASSIC B Length 50.0 mm | 1.967” Width 59.9 mm | 2.358” Height (to underside of Table Top) 17.3 mm | 0.681” 59.9 mm 2.358” Fig. 3: Product dimensions, DMIclassic B...
  • Page 14: Dmiclassic C

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 14 5.2.2 DMICLASSIC C Length 69.5 mm | 2.736” Width 137.2 mm | 5.404” Height (to underside of Table Top) 24.7 mm | 0.974” 137.2 mm Fig. 4: Product dimensions, DMIclassic C...
  • Page 15: Drilling Template

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 15 5.3 DRILLING TEMPLATE 5.3.1 DMICLASSIC B There are two variants for mounting. In the Standard Position the drilled holes should be 8 mm from the front edge of the Table Top and 43.8 mm apart. Alternatively, the drilled holes can be set to the Transportation Position, 24 mm from the front edge of the Table Top and 43.8 mm apart.
  • Page 16: Dmiclassic C

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 16 5.3.2 DMICLASSIC C When placing the drilling holes, it must be ensured that the Handset does not protrude from the front edge of the Table Top while in the retracted position. To ensure the correct position: •...
  • Page 17: Assembly

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 17 6 ASSEMBLY This chapter describes the process of installing the DMIclassic Family handset into the DYNAMIC MOTION System. SAFETY DURING ASSEMBLY WARNING Risk of death or serious injury through electric shocks DMIclassic Family handsets are electrical devices. Basic safety precautions must be taken at all times.
  • Page 18: Required Components

    Handset safely and securely in place. Exact specifications can be provided by LOGICDATA on request. INFO Screw Specifications for DMIclassic C The Mounting Screws are provided by LOGICDATA with the Handset. These are 16 mm in length, with a 3 mm thread and 8 mm head diameter. 6.3 PROCESS NOTICE DMIclassic C handset is equipped with a sliding mechanism and should always be mounted in the retracted position.
  • Page 19: System Information

    Table Top. Operate the DM System as normal. Green Light Flashing Position Reset Required. Perform a Position Reset Procedure Rapidly (System Manual, Chapter 4.7). NOTICE Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA for further information.
  • Page 20: Dmiclassic C

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 20 7.2 DMICLASSIC C When a DMIclassic C Handset is installed alongside the DYNAMIC MOTION system, error messages are displayed on the digital display panel. These are as follows: SIGNAL MESSAGE REQUIRED ACTIONS Overheating protection has been Wait for the overheated components to activated.
  • Page 21 Then, try again. Strain Gauge is defective Release all Keys and wait for 5 seconds. Then, try again. Contact LOGICDATA if the problem persists. Do not operate the DM System if components are broken. Error during pairing sequence Disconnect the Power Unit from the Mains.
  • Page 22: Operation

    Mains and check cable connections. NOTICE Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA for further information. 8 OPERATION Instructions for operating the system can be found in the DYNAMIC MOTION System Manual. A list of core features can be found below.
  • Page 23: Adjusting The Table Top Height

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 23 ADJUSTING THE TABLE TOP HEIGHT CAUTION Risk of minor or moderate injury through crushing Your fingers may be crushed when you attempt to change the height of the table. • Keep fingers away from moving parts •...
  • Page 24: Adjusting The Table To A Memory Position (Dmiclassic C Only)

    A risk assessment to demonstrate conformity to the requirements of Machinery Directive 2006/42/EC is required prior to use. • LOGICDATA is not liable for injuries or damage caused by activating the double- click function 1. Double-click the required Memory Position Key (e.g. 2) ▸...
  • Page 25: Changing The Height Display

    DMICLASSIC FAMILY - OPERATING MANUAL // PAGE 25 8.4 CHANGING THE HEIGHT DISPLAY (CM/INCH, DMICLASSIC C ONLY) DMIclassic C Handsets can display the height of the Table Top in both centimeters and inches. To change the displayed unit of measurement: 1.
  • Page 26: Maintenance

    Using a DMIclassic Family Handset alongside unauthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards. • Only use accessory parts produced or approved by LOGICDATA • Only use replacement parts produced or approved by LOGICDATA •...
  • Page 27 LOGICDATA LOGICDATA North America, Inc. Electronic & Software Entwicklungs GmbH 13617 Woodlawn Hills Dr. Wirtschaftspark 18 Cedar Springs, MI 49319 8530 Deutschlandsberg Austria Phone: +43 (0)3462 5198 0 Phone: +1 (616) 328 8841 Fax: +43 (0)3462 5198 1030 E-mail: office.na@logicdata.net E-mail: office.at@logicdata.net...