Table of Contents

Advertisement

Quick Links

DOCUMENT VERSION 7.0 | MARCH 2024
SMARTneo-2G
SMARTneo-3G
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for LOGICDATA SMARTneo-3G

  • Page 1 DOCUMENT VERSION 7.0 | MARCH 2024 SMARTneo-2G SMARTneo-3G Operating Manual...
  • Page 2 SMARTNEO OPERATING MANUAL // PAGE 2 SMARTneo-2G and SMARTneo-3G - Operating Manual Document version 7.0 / March 2024 This document was originally published in English. LOGICDATA Electronic & Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Telefon: +43 (0) 3462 51 98 0...
  • Page 3: Table Of Contents

    SMARTNEO OPERATING MANUAL // PAGE 3 CONTENTS General Information Other Applicable Documents Copyright Royalty-Free Use of Images and Text Trademarks Safety Target Audience General Safety Regulations Intended Use Reasonably Foreseeable Misuse Explanation of Symbols and Signal Words Liability Residual Risks Skilled Persons Notes for Resellers Scope Of Delivery...
  • Page 4 SMARTNEO OPERATING MANUAL // PAGE 4 Operation Adjusting the Table Top Height Saving a Memory Position 7.2.1 Using a Basic Hand Control 7.2.2 Using a Comfort Hand Control Adjusting the Table to a Memory Position 7.3.1 Using a Basic Hand Control 7.3.2 Using a Comfort Hand Control Software-Dependent Functions Low Speed Area...
  • Page 5: General Information

    LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind. Contact LOGICDATA to obtain text or images in an editable format (documentation@logicdata.net).
  • Page 6: Safety

    In general, the following safety regulations and obligations apply when handling the product: • Do not operate the SMARTneo-2G or SMARTneo-3G unless it is in a clean and perfect condition • Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment •...
  • Page 7: Explanation Of Symbols And Signal Words

    2.6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by: • Improper product use • Disregard of the documentation •...
  • Page 8: Residual Risks

    • Do not convert or modify the SMARTneo-2G / SMARTneo-3G in any way • Do not place the Cable of the SMARTneo-2G / SMARTneo-3G on heated surfaces • Do not immerse the SMARTneo-2G / SMARTneo-3G or its components in liquid.
  • Page 9 SMARTNEO OPERATING MANUAL // PAGE 9 WARNING Moderate risk of serious injury through electric shocks Inserting incorrect cables into the SMARTneo-2G / SMARTneo-3G may lead to death or serious injury through electric shocks. • Ensure only LOGICDATA-approved products are connected to the SMARTneo-2G / SMARTneo-3G •...
  • Page 10: Skilled Persons

    2.9 NOTES FOR RESELLERS Resellers are companies that purchase LOGICDATA products for installation in their own products. INFO For reasons of EU conformity and product safety, Resellers should provide end users...
  • Page 11: Scope Of Delivery

    LOGICDATA. Cables and Mounting Screws are not included in the scope of delivery. 4 PRODUCT The SMARTneo-2G / SMARTneo-3G is a Control Box for height-adjustable tables. There are variants of the SMARTneo-2G / SMARTneo-3G for specific domestic mains power supplies (e.g. EU or US). The exact va- riant is denoted by the product‘s order code.
  • Page 12: Key Product Features

    You must read the full product documentation of each product you are connecting to the SMARTneo-2G / SMARTneo-3G to ensure correct assembly and the safety of all users. Fig. 2 shows all the plug ports and connections featured in the SMARTneo-2G / SMARTneo-3G.
  • Page 13: Dimensions

    SMARTNEO OPERATING MANUAL // PAGE 13 4.2 DIMENSIONS 218,2 mm 8.590” 200,0 mm 7.874” 84,5 mm 3.326” Fig. 3: Dimensions SMARTneo-2G / SMARTneo-3G 4.2.1 DRILLING TEMPLATE 49,2 mm (± 0,15 mm) 1.937” (± 0.006”) Fig. 4: Drilling Template SMARTneo-2G / SMARTneo-3G...
  • Page 14: Assembly

    SMARTNEO OPERATING MANUAL // PAGE 14 The mounting points for the SMARTneo-2G and SMARTneo-3G have a diameter of 5,5 mm. The drilled holes must be 200 mm (lengthways) and 49,2 mm (widthways) apart. The entire housing of the SMARTneo-2G and SMARTneo-3G must be underneath the table.
  • Page 15: Required Components

    Tool Screwdriver INFO The mounting points for the SMARTneo-2G / SMARTneo-3G have a diameter of 5,5 mm. The Mounting Screws should hold the SMARTneo-2G / SMARTneo-3G safely and securely in place. Exact specifications can be provided by LOGICDATA on request.
  • Page 16: Completing Assembly

    Example Clamp Fig. 5: Positioning the Cable Clamps 5.4 COMPLETING ASSEMBLY After the SMARTneo-2G / SMARTneo-3G is attached to the Table Top, you must connect the Control Box to the system. Instructions for this can be found in the next chapter.
  • Page 17: Connecting The System

    Assembly instructions must be included in your end user Operating Manual. SYSTEM CONFIGURATION The SMARTneo-2G / SMARTneo-3G can be used to create a variety of Table Systems. This Manual describes the connection of table systems in which only one Control Box will be connected. For Table Systems with more than one Control Box, refer to the SMARTneo-2G Cascading Manual (applies also to SMARTneo-3G) for assembly and safety advice.
  • Page 18: Required Components: System With 2 Actuators

    User Interface (see Chapter 6.3) Mains Cable (2-pin connection, C7) 6.2 CONNECTING ACTUATORS Plug the Actuator(s) into the designated Plug Port(s) on the SMARTneo-2G / SMARTneo-3G (M1/M2 [optio- nal]). NOTICE Ensure that the Actuator(s) have been safely assembled into the Height-Adjustable Columns before connecting.
  • Page 19: Connection Via The Dc/Com Port (Optional)

    The DC/COM interface of the SMARTneo-2G / SMARTneo-3G may only be used to connect compatible, cer- tified, LOGICDATA approved external devices. The external device must have a current-limiting component in its output circuit (e.g. a fuse) to limit the maximum current to 10 A. Contact LOGICDATA for instructions and safety advice.
  • Page 20: Configuration Example

    4. Release the DOWN Key ▸ The Position Reset Procedure is complete. INFO If your SMARTneo-2G / SMARTneo-3G has been parameterized with additional stopp- ing points (e.g. a Container Stop Position), repeat Step 3 until the table has moved upwards again.
  • Page 21: Operation

    SMARTNEO OPERATING MANUAL // PAGE 21 7 OPERATION CAUTION Risk of minor or moderate injury through uncontrolled movement The table may not always stop exactly at the expected position. Failure to anticipate the table‘s movements may lead to minor or moderate injury through crushing. Wait until the system has completely stopped before attempting to use the table CAUTION Risk of minor or moderate injury through unsecured objects...
  • Page 22: Adjusting The Table Top Height

    SMARTNEO OPERATING MANUAL // PAGE 22 ADJUSTING THE TABLE TOP HEIGHT CAUTION Risk of minor or moderate injury through crushing Your fingers may be crushed when you attempt to change the height of the table. • Keep fingers away from moving parts •...
  • Page 23: Using A Comfort Hand Control

    INFO The double-click function is available only for SMARTneo-2G / SMARTneo-3G Control Boxes sold in US markets. It is an option configured by LOGICDATA only on request. INFO If you press any Key while the table moves to a Memory Position, the Table Top will...
  • Page 24: Using A Comfort Hand Control

    INFO The double-click function is available only for SMARTneo-2G / SMARTneo-3G Control Boxes sold in US markets. It is an option configured by LOGICDATA only on request. INFO If you press any Key while the table moves to a Memory Position, the Table Top will...
  • Page 25: Software-Dependent Functions

    A risk assessment to demonstrate conformity to the requirements of Machinery Directive 2006/42/EC is required prior to use. • LOGICDATA is not liable for injuries or damage caused by activating the double-click function. 1. Double-click the required Memory Position Key (e.g. 2).
  • Page 26: Safety Area

    1. Press 3x DOWN followed by 1x UP and 1x DOWN with an approximate delay of half a second between the press and release of the button each time. ▸ The SMARTneo-3G has now been reset to its factory settings. It is now in the same state as it was during the first start-up.
  • Page 27: Using A Comfort Hand Control

    ▸ The display shows S 0. 3. Press the SAVE Key. ▸ The SMARTneo-2G / SMARTneo-3G has now been reset to its factory settings. It is now in the same state as it was during the first start-up. 8.4 CONTAINER STOP AND SHELF STOP POSITIONS These features can limit the movement area of the Table Top (if e.g.
  • Page 28: Using A Comfort Hand Control

    SMARTNEO OPERATING MANUAL // PAGE 28 To Delete a Container or Shelf Stop Position: 1. Press the UP or DOWN Key to move the Table Top to the top half (to delete a Shelf Stop Position) or bottom half (Container Stop Position) of the movement area. 2.
  • Page 29: Changing The Displayed Unit Of Measurement

    SMARTNEO OPERATING MANUAL // PAGE 29 ▸ Press the SAVE Key. ▸ The height display is now set to the new Table Top height (e.g. 73 cm). 8.6 CHANGING THE DISPLAYED UNIT OF MEASUREMENT (CM / INCH) Comfort Hand Controls can display the height of the Table Top in both centimeters and inches. To change the displayed unit of measurement: 1.
  • Page 30: Actuator Setup

    Control Box will continue to be used. Options are as follows: • If you wish to change the type of LOGICDATA SLIMdrive connected to the Control Box (e.g. for SLIMdrive-660s to SLIMdrive-500), but you do not want to change the number of connected SLIMdrives, go to Chapter 9.2, SLIMdrive Detection: Changing to a Different SLIMdrive Type.
  • Page 31: Auto-Detect: Changing The Number Of Slimdrives

    NOTICE Auto-Detect settings depend on the parameterization of the Control Box. Contact LOGICDATA before attempting to change the table configuration. The Control Box can automatically detect how many SLIMdrives are connected to the system. This means that you can change the number of SLIMdrives the Control Box must control without changing the parame- terization of the control box.
  • Page 32 SMARTNEO OPERATING MANUAL // PAGE 32 This function allows you to manually change the number of Actuators that the Control Box will control. Proceed as follows to manually change these settings. 1. Press and hold the following Keys for 3 seconds: •...
  • Page 33: Troubleshooting

    Poor plug connection Ensure that all plugs have been connected properly The Actuator is defective Replace the Actuator. Contact LOGICDATA if the problem persists The User Interface is defective Replace the User Interface. Contact LOGICDATA if the problem persists...
  • Page 34: Click Codes

    Read the table below to find the correct response to the error code shown. The display shows an error number. CODE MESSAGE REQUIRED ACTIONS Internal Error Channel 1 Disconnect the Control Box from the Mains. Contact LOGICDATA for further information. Internal Error Channel 2...
  • Page 35 Defect Channel 2 Overcurrent Motor M1 Check that nothing is blocking the table‘s range of movement. Remove excess load from the tab- le. Contact LOGICDATA for further information. Overcurrent Motor M2 Overcurrent Motor Group Plug detected in M1 Plug in the correct motor. Ensure all cables are connected correctly.
  • Page 36 Contact LOGICDATA for further information if the problem persists. Connection Error During Cascading NOTICE Do not operate the table system if problems persist. Contact LOGICDATA for further information. NOTICE The Middle Switch is only fitted to certain versions of the Control Box. Contact...
  • Page 37: Additional Information

    Intelligent System Protection (ISP) is LOGICDATA’s collision detection system. It aims to reduce the risk of system damage when using LOGICDATA products. When a collision is detected, all Actuators stop im- mediately and move back in the opposite direction for a few seconds (see 11.2.2 Drive Back Function). The SMARTneo-2G features integrated collision detection function via the Light Barrier sensor, and SMARTneo- 3G via gyroscope.
  • Page 38: Disabling Sensor Detection (S3 Menu)

    In certain assembly variants, it may not be possible to achieve accurate readings from the integrated sensor. In this case, it is possible to manually switch the ISP sensor on and off. LOGICDATA does not reccomend using the Control Box without a functioning ISP sensor. To avoid system damage, the ISP sensor should only be switched off when absolutely necessary, and only with prior approval from LOGICDATA.
  • Page 39: Maintenance

    SMARTNEO OPERATING MANUAL // PAGE 39 11.3 MAINTENANCE The Control Box is maintenance free for its entire service lifetime. If cleaning is required, wipe the housing with a soft, dry cloth. WARNING Moderate risk of serious injury through electric shocks While cleaning or maintaining the Control Box, liquid intrusion may lead to serious injury through electric shocks.
  • Page 40 LOGICDATA LOGICDATA North America, Inc. Electronic & Software Entwicklungs GmbH 13617 Woodlawn Hills Dr. Wirtschaftspark 18 Cedar Springs, MI 49319 8530 Deutschlandsberg Austria Phone: +43 (0)3462 5198 0 Phone: +1 (616) 328 8841 Fax: +43 (0)3462 5198 1030 E-mail: office.na@logicdata.net E-mail: office.at@logicdata.net...

This manual is also suitable for:

Smartneo-2g

Table of Contents