12.0) ELECTRICAL CONNECTIONS

The electrical wiring to this heater must be installed in accordance with the latest or current National
a.
Regulations and any Local Regulations, which apply.
Electrical supply
Current rating
Fuse externally
1. Using a suitable cable connector and twin core and earth PVC covered flexible supply cable, (0.5 mm
1.
National or Local standard specification) connect the fan leads to the 3 pin plug provided (fastenings
1.
pack) as follows:-
Brown (red)
Blue (Black)
Green/Yellow
Connect this 3 pin plug to the electrical socket (marked
consideration should be given to the required clearance from combustibles (see section 4.0) when routing
the cable from Fan to Control Box.
2. Using twin core and earth flexible supply cable, as suitable for 230V~50Hz 125W supply, connect the 3 pin
electrical socket provided (fastenings pack) as follows:-
Brown (red)
Blue (Black)
Green/Yellow
Connect this electrical socket to the 3 pin plug (marked 230V~50Hz) mounted in the side of the Control
Box.
External fuse rating required - 3A
NOTE: It is important for the correct function of the appliance for the polarity of the electrical supply to be
correct.
Single Heaters per Thermostat connection diagram
Fig. 31
230V~50Hz 125W
0.55
3A
-
to terminal marked L
-
to terminal marked N
-
to terminal marked 7
-
to terminal marked L
-
to terminal marked N
-
to terminal marked 7
-44-
) mounted in the side of the Control Box. Due
to
2
Form #44201100
Oct 2019