8.0) ELECTRICAL CONNECTIONS

1. All electrical wiring shall conform to the latest edition of the National Electrical Code (ANSI/NFPA No.
70), or the code legally authorized in the locality where the installation is made. DO NOT use phone cable
for electric supply wiring.
2. The electrical system must be electrically grounded in accordance with the National Electrical Code
(ANSI/NFPA No. 70 - latest edition) or the Canadian Electrical Code (C22.1 Part 1 - latest edition) as
appropriate.
3. Each brooder requires a 120 volt - power supply
4. A Thermostat (available as an accessory, Part No. 30525010, or an environmental controller, etc.) is also
required for each brooder or group of brooders as shown in the schematic. The schematic below shows a
group of four (4) brooders controlled by one (1) thermostat. Additional zone groups having more or less
brooders can be added. These should be wired the same as shown in the schematic.
Contact the factory for pricing and availability for the Thermostat.
A. INTERNAL CONNECTION WIRING DIAGRAM – 120V Power Supply
Terminal Designations
B. GND
Burner Ground
L1
Power Supply - Hot
V2
Valve Ground
L2
Power Supply - Neutral
V1
Valve Power
NC
-NOT USED-
FC-
Flame Current –
FC+
Flame Current +
–18–
Form No. 43539510
May 2020