Main Burner and Orifice: Check the Main burner and orifice; remove any dirt or debris including spider webs.
See Sections 18.2 and 18.3 .
Electrical Wiring: Check that all the electrical connections are sound and that the wiring is undamaged.
Replace damaged wires as necessary.
Air Inlet / Baffle Plate: Check that the air inlet holes in the Baffle Plate, which is clamped between the
Control Box side panel and the Air Inlet flange, are clear from obstructions. Check also, that the wire mesh
panel of the Air Inlet is clean. Clean as necessary using a soft brush. In the case of an appliance having a
ducted air supply, it will be necessary to disconnect the flexible ducting from the Air Inlet by first releasing
the hose clip. If it is necessary to remove the Air Inlet to adequately clean the Baffle Plate it will be
necessary to replace the gasket seal (see Section 18.8.
Door Seal: Check the condition of the seal around the Control Box door and replace as necessary.
IMPORTANT: The appliance will not function unless the seal around the control box door is sound and the
door secured with the two toggle latches.
Flue Pipes: For flued appliances it is important that periodic sweeping of the flue is carried out according to
the National or Local regulations in force.
Auxiliary Controls: Room thermostats, time switches, frost thermostats etc should be checked to ensure
correct functioning, and are set to the user requirements.
Re-assemble and Commission: Re-assemble the appliance in reverse order and commission in accordance
with the instructions contained in Section 15.0.