6. Insert turbulators (where required) into the tube sections as described below.
IV. Assemble the turbulators together by interlocking the slotted ends.
V. Slide these into the tubes at the end of the heater as shown for Linear Models.
VI. Align the turbulator end flush with end of tube.
Note: Refer to the table below for the number of turbulators required for each heater model.
Table 15.
Fig. 22d
7. Position the lower reflector panels over the tube support/hanger brackets. Arrange the reflector panels to
the dimensions shown in section 8.0. Note: The reflectors MUST be positioned in accordance with the
dimensions stated because the side panels provided with the heater are designed to cover the entire length
of the reflectors and therefore if the location of the reflectors does not match these dimensions then the
side panels will not fit. See table 16 and figure 22e below:
MODEL
Turbulator Sections
ADL 25
65mm x 572mm
90mm x 610mm
ADL 30
90mm x 610mm
ADL 35
90mm x 610mm
ADL 40
90mm x 610mm
ADL 45
-34-
Number
6
9
4
8
4