8 Troubleshooting

Fig.92
Fitting the electrical connections
and air supply hose
11
9
10
7.5

Finalising work

8
Troubleshooting
8.1

Error codes

Tab.82
Error codes are displayed at three different levels
Code
Type
A .00.00
Warning
(1)
H .00.00
Blocking
(1)
E .00.00
Lock out
(1)
(1) The first letter indicates the type of error.
(2) For some blocking errors, this checking interval is ten minutes. In those cases, it may seem that the controls do not start automatically.
Wait ten minutes before resetting.
72
9. Connect the electrical connections to the fan.
10. Lock the fan power plug with the safety slides.
11. Mount the air supply hose to the air box.
AD-3001590-01
1. Fit all removed parts in the reverse order, but do not close the casing
yet.
Caution
During inspection and maintenance operations, always replace all
gaskets on the parts removed.
2. Fill the siphon with water.
3. Put the siphon back in place.
4. Carefully open all system and supply valves which were closed to
carry out the maintenance.
5. Fill the central heating system with water if necessary.
6. Vent the central heating system.
7. Top up with more water if necessary.
8. Check the tightness of the gas and water connections.
9. Put the boiler back into operation.
10. Carry out an auto-detect when a control board has been replaced or
removed from the boiler.
11. Set the boiler to full load and carry out a gas leak detection and a
thorough visual check.
12. Set the boiler to normal operation.
13. Close the casing.
The Gas 320/620 Ace is fitted with an electronic regulation and control
unit. The heart of the control is a e-Smart microprocessor, which controls
and also protects. In the event of an error, a corresponding code is
displayed.
Description
The controls continue to operate, but the cause of the warning must be investigated. A
warning can change into a blocking or lock-out.
The controls will stop normal operation, and will check with set intervals if the cause of
the blocking still exists.
Normal operation will resume when the cause of the blocking
(2)
has been rectified. A blocking can become a lock-out.
The controls will stop normal operation. The cause of the lock-out must be rectified and
the controls must be reset manually.
The meaning of the code can be found in the various error code tables.
Important
The error code is needed to find the cause of the error quickly and
correctly and for any support from Remeha.
7734325 - v.07 - 22092022