7.4.8

Cleaning the siphon

Fig.88
Cleaning the siphon
2
Fig.89
Filling the siphon
6
4
7.4.9

Assembly after maintenance

Fig.90
Mounting the burner
4
Fig.91
Mounting the fan
5.2
5.3
5.1
7
6
7734325 - v.07 - 22092022
AD-3001605-01
7
5
8
AD-3001606-02
2
3
1
AD-3001588-01
8
AD-3001589-01
1. Remove the siphon.
2. Clean the siphon with water.
3. Put the siphon back in place.
4. Turn the clip counterclockwise to access the sealing cap.
5. Remove the sealing cap from the condensate collector.
6. Fill the siphon with water up to the mark via the condensate collector.
Danger
The siphon must always be sufficiently filled with water. This
prevents flue gases from entering the room.
7. Refit the sealing cap on the condensate collector.
8. Turn the clip clockwise to secure the sealing cap.
1. Mount the burner.
The burner has two slots at the front. Position these over the two
pins at the burner opening.
2. Place a new burner gasket.
3. Mount the adapter.
4. Mount the new ionisation/ignition electrode.
5. Mount the fan assembly:
5.1. Place the non-return valve.
5.2. Place the new gasket.
5.3. Mount the fan.
6. Tighten the nuts on the adapter.
7. Tighten the nuts on the venturi.
8. Mount the air supply hose to the venturi.