Laguna Tools SmartShop Maker Owner's Manual page 60

Table of Contents

Advertisement

Error Code
Sub program no M99
Too many G code
Too many (I,J,K) triples
Use undefined workpiece
coordinate
Invalid are radius value
Macro stack is full or access
fail
Macro stack is empty
Invalid macro arguments
Macro program error
Tool length offset change at
arc
60
SmartShop|Maker Owner's Manual
Potential Issue(s)
Programming error
Programming error
Programming error
Programming error
Programming error
1. Storing value in STACK
(PUSH) is too much.
2. Arguments in
STKTOP[]exceeds the value
storing in STACK.
The numbers of Push commands
and Pop commands are not the
same.
Once Macro finds out the
unreasonable situation, machining
program will be stopped, and alarm
will appear.
Programming error
Programming error
Resolution(s)
Write M99 at the end of
subprogram.
Dividing that single block into
others single block that has less
than 10G codes.
Check the machining program.
Decide the working plane and
input G17, G18, or G19.
Check the program and
recalculate.
1. Stack is full, no using push
command.
2. Input reasonable argument
in STKTOP[].
Check the program to ensure
that the number of Push
commands is the same with that
of Pop commands.
According to display content of
alarm to find out where error is.
Please check the machining
program.
Please check the machining
program.