Laguna Tools SmartShop Maker Owner's Manual page 47

Table of Contents

Advertisement

Error Code
DDA command overflow
SmartShop|Maker Owner's Manual
Potential Issue(s)
1. DDA software time setting
value (interpolation time
interval, parameter Pr3293) is
too long.
2. Motion velocity is too fast.
3. Servo resolution is set too
high.
4. Backlash compensation or
pitch compensation is too
large.
5. Compensation is enabled
before booting.
Resolution(s)
1. Recommend that low
interpolation time interval
setting (parameter 3203) is
not less than 2000.
2. Reduce the velocity to do
the test if max rapid travel
federate is too high (Pr462-
Pr480).
3. Reduce the servo resolution
setting to do test (encoder
and CNC Pr61-Pr80).
4. If mechanical compensation
time constant is set
(parameter 1401-1420),
cancel the mechanical
compensation setting to do
test and find the best
setting.
5. If system had set feed
forward (parameter 581-
600), cancel feed forward
setting to do test and find
the best setting.
6. Please contact staff of
machinery manufacturer to
solve problem.
47