Laguna Tools SmartShop Maker Owner's Manual page 46

Table of Contents

Advertisement

Error Code
Machine date file write fail
many times, re-calibrate
before machining
Machine data file fault error,
re-calibrate before machining
and do scandisk
A,B feedback signal error
Error counter overflow
46
SmartShop|Maker Owner's Manual
Potential Issue(s)
1. CF card may be seriously
damaged and CF card should
be processed soon.
2. Registry.dat or registry.mir file
is set to read-only.
3. System file cannot handle
resource well, lead to writing
file unsuccessfully.
1. CF card may be seriously
damaged and CF card should
be processed soon.
2. Registry.dat or registry.mir file
is set to read-only.
3. System file cannot handle
resource well, lead to writing
file unsuccessfully.
When servo type is set EMP2,
internal axis card will automatically
detect the A, B encoder signals, if
signal error or have A-phase
signal, but no B-phase signal, this
alarm will appear.
When servo type is set 0(EMP2),
4(PMC4), 5(SERVO6), internal
axis card will automatically detect
the A, B encoder signals, if signal
error or too much input signal,
counter overflow will appear.
Resolution(s)
1. Scan CF card.
2. Check whether the
machining setting is correct.
3. Reboot.
1. Scan CF card.
2. Check whether the
machining setting is correct.
3. Reboot.
Check the servo cable or
replace the axis card.
Check the servo cable or
replace the axis card.