Laguna Tools SmartShop Maker Owner's Manual page 43

Table of Contents

Advertisement

Error Code
Fatal low memory, memory
space is less than 100K
The number of interpolation
loss times is bigger than 100
Axis Group setting error
SmartShop|Maker Owner's Manual
Potential Issue(s)
Users design too many texts and
pictures when they design CE
human-machine interface and
make the capacity of system
memory less than 100k.
1. Axis card is damaged.
2. System resource is exhausted.
3. The setting of interpolation
time interval (Pr3203) is too
small.
Parameter setting error.
Ex: Assume the machine exists
XYZ axes, each associated
axis group is set as follows:
Pr701 = Pr702 = Pr703
=5(XYZ axes belong to the 1
group + 3
group)
rd
Suppose that Pr731 = 3(axis
groups in CNC are the 1
spindle group the 2
group, and the 3
spindle
rd
group). It means that the 2
axis group is not covered by an
axes and one alarm will
appear.
Human-machine interface of
controller should simplify
components, only design
effective variables and
scripts to avoid the low
memory phenomenon.
1. Replace the hardware of
axis card.
2. Replace a better
motherboard.
3. Set longer interpolation time
interval.
st
Please check the matching
between Pr701 ~ Pr716 and
Pr731.
st
spindle
nd
nd
Resolution(s)
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartshop m

Table of Contents