Error Code
Invalid axis board setting, IO
will not work
Parameter storage access
failure, system halt
SmartShop|Maker Owner's Manual
Potential Issue(s)
1. Controllers parameters are
set wrong.
2. CUP BIOS sets wrong.
3. Axis card error or jump setting
error.
4. Axis card and ISA SLOT have
poor contact or axis card
represses ISA SLOT.
The first CF card error
Resolution(s)
1. Check whether the setting
parameter Pr1 of the
controller is suitable for the
corresponding hardware
specifications (see
application handbook-
parameter explanation).
2. Check whether IRQ11
setting of BIOS is Legacy
ISA.
3. Check jump of axis card.
4. Check whether discontinuity
signal ISR of the first card is
disconnected (other axis
cards must open).
5. Replacement the Axis card
to avoid the poor contact
between axis card and ISA
slot.
1. Take the first CF card out,
insert into CF card reader,
connect to the PC and
repair CF card on PC, after
the recopy backup
parameters to C:\CNC\APP
(file of backup parameter is
PARAM.LKN).
2. Replace the first CF card
(please note that the first CF
card needs DOS boot
system and CNC kernel
software).